5 - 162
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Storage item
Storage details
Md.106
Load inertia ratio
•
The "
Pr.112
Load inertia ratio" servo parameter value set to the servo amplifier
is stored. (Unit: 0.1%)
(When auto tuning is valid, the value calculated by auto tuning is stored.)
Md.107
Position loop gain 1
•
The "
Pr.113
Position loop gain 1" servo parameter value set to the servo
amplifier is stored. (Unit: rad/s)
(When auto tuning is valid, the value calculated by auto tuning is stored.)
Md.108
Speed loop gain 1
•
The "
Pr.114
Speed loop gain 1" servo parameter value set to the servo
amplifier is stored. (Unit: rad/s)
(When auto tuning is valid, the value calculated by auto tuning is stored.)
Md.109
Position loop gain 2
•
The "
Pr.115
Position loop gain 2" servo parameter value set to the servo
amplifier is stored. (Unit: rad/s)
(When auto tuning is valid, the value calculated by auto tuning is stored.)
Md.110
Speed loop gain 2
•
The "
Pr.116
Speed loop gain 2" servo parameter value set to the servo
amplifier is stored. (Unit: rad/s)
(When auto tuning is valid, the value calculated by auto tuning is stored.)
Md.111
Speed integral
compensation
•
The "
Pr.117
Speed integral compensation" servo parameter value set to the
servo amplifier is stored. (Unit: ms)
(When auto tuning is valid, the value calculated by auto tuning is stored.)
Md.112
Servo amplifier software
No.
•
The used servo amplifier software No. is stored.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......