14 - 78
MELSEC-A
14 TROUBLESHOOTING
14.3.6 Warnings detected by MR-J2-03B5
Warning
code
Servo
amplifier
LED display
Name Definition
Occurrence
factor
2141 E1
Overload
warning
There is a possibility that overload
1 (error code: 2050) or overload 2
(error code: 2051) may occur.
Load increased to 85% or more of overload 1 (error
code: 2050) or overload 2 (error code: 2051)
occurrence level.
2144 E4
Parameter
warning
Parameter is outside the setting
range.
Parameter was set from AD75 to value outside
setting range.
2146
E6
Servo forced stop
EM1-P24G open.
Forced stop was made valid.
(EM1-P24G opened)
1. EMG (pin 6) or EMG* (pin 16) in SSCNET cable
is open.
2. Servo amplifier connector faulty
2147 E7
Controller
emergency stop
Servo system controller
emergency stop was input.
3. AD75 connector faulty
2149 E9
Main circuit OFF
warning
Servo turned ON with main circuit
power OFF.
Servo turned ON with main circuit power OFF.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......