12 - 25
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
12.4 Functions to limit the control
Functions to limit the control include the "speed limit function", "torque limit function",
"software stroke limit", and "hardware stroke limit". Each function is executed by
parameter setting or sequence program creation and writing.
12.4.1 Speed limit function
The speed limit function limits the command speed to a value within the "speed limit
value" setting range when the command speed during control exceeds the "speed limit
value".
The details shown below explain about the "speed limit function".
(1) Relation between the speed limit function and various controls
(2) Precautions during control
(3) Setting the speed limit function
(1) Relation between the speed limit function and various controls
The following table shows the relation of the "speed limit function" and various
controls.
Control type
Speed limit function Speed limit value
Machine zero point return control
Zero point
return
control
High-speed zero pint return control
1-axis linear control
2-axis linear interpolation
control
1-axis fixed-dimension
feed control
2-axis fixed-dimension
feed control (interpolation)
Position
control
2-axis circular interpolation
control
Speed control
Speed/position changeover control
Pr.7 Speed limit
value
Current value change
–
Main
positioning
control
Other
control JUMP command
–
Setting value invalid
JOG operation
Pr.32 JOG speed
limit value
Manual
control
Manual pulse generator operation
Setting not possible.
: Always set
: Setting not possible
– : Setting not required (Setting value is invalid. Use the initial values or setting values
within a range where no error occurs.)
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......