9 - 37
MELSEC-A
9 MAIN POSITIONING CONTROL
(2) 2-axis circular interpolation control with auxiliary point designation
(INC circular interpolation)
In the increment system, 2-axis circular interpolation control with auxiliary point
designation, addresses established by a machine zero point return on a 2-axis
coordinate plane are used. Positioning is carried out from the current stop position
(start point address) to a position at the end of the movement amount set in
" Da.5 Positioning address/movement amount", in an arc path that passes
through the auxiliary point address set in " Da.6 Arc address".
The resulting control path is an arc having as its center the intersection point of
perpendicular bisectors of the following:
(1) A straight line between the start point address (current stop position) and
auxiliary point address (arc address) calculated from the movement amount to
the auxiliary point.
(2) A straight line between the start auxiliary point address (arc address) and end
point address (positioning address) calculated from the movement amount to
the end point.
Reverse direction
Forward direction
Movement amount to the end point
Movement amount
to the auxiliary point
Movement amount
to the end point
Arc center
Start point
address
Forward direction
Reverse direction
Movement amount
to the auxiliary point
Movement by circular interpolation
End point address
(arc address)
(positioning address)
Auxiliary point address
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......