6 - 37
MELSEC-A
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
(2) Types of stop processes
The operation can be stopped with deceleration stop, sudden stop or immediate
stop.
(1) Deceleration stop
The operation stops with "deceleration time 0 to 3" ( Pr.9 , Pr.29 , Pr.30 ,
Pr.31 ).
Which time from "deceleration time 0 to 3" to use for control is set in positioning
data ( Da.4 ).
(2) Sudden stop
The operation stops with " Pr.37 Sudden stop deceleration time".
(3) Immediate stop
The operation does not decelerate.
The AD75 immediately stops the position/speed command output, but the
operation will coast for the droop pulses accumulated in the servo amplifier's
deviation counter.
Actual deceleration time
Set deceleration time
Positioning speed
Actual sudden stop
deceleration time
Pr.37 Sudden stop
deceleration time
Coast for the droop pulses accumulated
in the servo amplifier's deviation counter.
Positioning speed
Positioning speed
Fig. 6.14 Types of stop processes
REMARK
*
1
"Deceleration stop" and "sudden stop" are selected with the details parameter
"stop group 1 to 3 sudden stop selection". (The default setting is "deceleration
stop".
)
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......