9 - 28
MELSEC-A
9 MAIN POSITIONING CONTROL
Restrictions
An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning
operation.
•
If the movement amount of each axis exceeds "1073741824 (=2
30
)" at the
setting of "0: Composite speed" in "
Pr.21
Interpolation speed designation
method".
An error "outside linear movement amount range" (error code: 504) will occur
at the positioning start.
(The maximum movement amount that can be set in "
Da.5
Positioning
address/movement amount" is "1073741824 (=230)"
Positioning data setting example
The following table shows setting examples when "2-axis linear interpolation
control (INC linear 2)" is set in positioning data No. 1 of axis 1. (The required
values are also set in positioning data No. 1 of axis 2.)
Axis
Setting item
Axis 1
(reference
axis) setting
example
Axis 2
(interpolation
axis) setting
example
Setting details
Da.1
Operation pattern
Positioning
complete
–
Set "Positioning complete" assuming the next positioning
data will not be executed.
Da.2
Control method
INC linear 2
–
Set increment system 2-axis linear interpolation control.
Da.3
Acceleration time
No.
1 –
Designate the value set in "
Pr.26 Acceleration time 1" as
the acceleration time at start.
Da.4
Deceleration time
No.
0 –
Designate the value set in "
Pr.9 Deceleration time 0" as
the deceleration time at deceleration.
Da.5
Positioning address/
movement amount
9000.0
µ
m -3000.0
µ
m
Set the movement amount. (Assuming "mm" is set in
"
Pr.1 Unit setting".)
Da.6
Arc address
–
–
Setting not required (setting value will be ignored).
Da.7
Command speed
6000.00
mm/min
–
Set the speed during movement.
Da.8
Dwell time
500ms
–
Set the time the machine dwells after the positioning stop
(position command output stop) to the output of the
positioning complete signal.
Ax
is 1 Positioning data N
o
. 1
Da.9
M code
10
–
Set this when other auxiliary operation commands are
issued in combination with the No. 1 positioning data.
* Refer to section "5.3 List of positioning data" for information on the setting details.
POINT
The speed limit does not function for the speed calculated by the AD75 during
interpolation control. Because of this, observe the following precautions when
setting the speed.
•
When the "composite speed" is set, set a value so the speed for each axis does
not exceed the " Pr.7 Speed limit value".
•
When the "reference axis speed" is set, set so the major axis side becomes the
reference axis. If the minor axis side is set as the reference axis, the major axis
side speed may exceed the " Pr.7 Speed limit value".
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......