12 - 30
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
12.4.3 Software stroke limit function
In the "software stroke limit function" the address established by a machine zero point
return is used to set the upper and lower limits of the moveable range of the workpiece.
Movement commands issued to addresses outside that setting range will not be
executed.
In the AD75, the "current feed value" and "machine feed value" are used as the
addresses indicating the current position. However, in the "software stroke limit
function", the address used to carry out the limit check is designated in the " Pr.15
Software stroke limit selection". (Refer to section "9.1.4 Confirming the current value"
or details on the "current feed value" and "machine feed value".)
The upper and lower limits of the moveable range of the workpiece are set in " Pr.13
Software stroke limit upper limit value"/ " Pr.14 Software stroke limit lower limit value".
The details shown below explain about the "software stroke limit function".
(1) Differences in the moveable range when "current feed value" and "machine feed
value" are selected.
(2) Software stroke limit check details
(3) Relation between the software stroke limit function and various controls
(4) Precautions during software stroke limit check
(5) Setting the software stroke limit function
(6) Invalidating the software stroke limit
(7) Setting when the control unit is "degree"
(1) Differences in the moveable range when "current feed value" and
"machine feed value" are selected.
The following drawing shows the moveable range of the workpiece when the
software stroke limit function is used.
FLS
RLS
Workpiece moveable range
Software stroke limit (lower limit)
Software stroke limit (upper limit)
Fig. 12.15 Workpiece moveable range
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......