12 - 17
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
Calculation example
(Conditions)
Movement amount per pulse
No. of pulses per rotation
Unit magnification
: 500 (
µ
m/rev)
: 12000 (pulse/rev)
: 1
(Positioning results)
Command movement amount
Actual movement amount
: 100mm
: 101mm
(Compensation amount)
AL' 5
×
10
3
101
×
10
3
5050 101
AP'
=
12000
×
101
×
10
3
=
12000
=
240
Movement amount per pulse
No. of pulses per rotation
Unit magnification
: 101 (
µ
m/rev)
: 240 (pulse/rev)
: 1
5)
Set the post-compensation " Pr.2 No. of pulses per rotation (Ap')",
" Pr.3 Movement amount per rotation (Al')", and " Pr.4 Unit
magnification (Am')" in the parameters, and write them to the AD75.
The set details are validated at the rising edge (OFF ON) of the
PLC READY signal (Y1D).
Setting item
Setting
value
Setting details
Pre-compensation
value
Pr.2
No. of pulses per
rotation
A p '
Set the post-compensation value.
Ap
Pr.3
Movement
amount per
rotation
A l '
Set the post-compensation value.
Al
Pr.4
Unit
magnification
A m '
Set the post-compensation value.
Am
* Refer to section "5.2 List of parameters" for setting details.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......