12 CONTROL AUXILIARY FUNCTIONS
[3] Precautions during control
The following precautions are for the case where the "infinite length mode" is selected
as the absolute position restoration mode and the absolute position is detected for
infinite positioning control.
(1) The following table indicates usable hardware versions and software versions
of the modules.
Model name
Hardware version
Software version
AD75M1
F or later
AD75M2
F or later
AD75M3
G or later
A1SD75M1
G or later
A1SD75M2
G or later
A1SD75M3
H or later
W or later
If the hardware version is earlier than the one indicated in the above table and
the software version is as indicated in the above table, selection of the "infinite
length mode" in "
Pr.59
Absolute position restoration selection" will result in an
error "absolute position restoration selection error" (error code: 998) when the
PLC READY signal (Y1D) turns from OFF to ON.
(2) To switch the absolute position restoration mode to the "infinite length mode",
make a machine zero point return after satisfying the following conditions (a) to
(c). If any of (a) to (c) is not satisfied, the absolute position restoration mode
turns to the "standard mode" on completion of the machine zero point return.
(a) "
Pr.1
Unit setting" is "2: degree".
(b) The software stroke limit function (refer to section 12.4.3) is invalid.
(c) "
Pr.101
Amplifier setting" is "1: Absolute position detection valid".
(3) "
Md.30
Machine feed value" cannot be used.
(4) The following control methods cannot be executed.
•
"
Da.2
Control method" "03
H
: 1-axis fixed-dimension feed control"
•
"
Da.2
Control method" "06
H
: 2-axis fixed-dimension feed control"
•
"
Da.2
Control method" "0F
H
: Speed/position changeover control (forward
run)"
•
"
Da.2
Control method" "10
H
: Speed/position changeover control (reverse
run)"
•
"
Da.2
Control method" "11
H
: Current value change"
If any of the above is executed, an error "control method setting error" (error
code: 524) occurs.
(5) The following positioning starts cannot be executed.
•
Positioning start when the " Cd.11 Positioning start No." is "9002: High-speed
zero point return"
•
Positioning start when the " Cd.11 Positioning start No." is "9003: Current
value change"
If either of the above is executed, an error "outside start number range" (error
code: 543) occurs.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......