5 - 57
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
[Table 1]
Pr.1
setting value
Value set with peripheral device
(unit)
Value set with sequence program
(unit)
0 : mm
–214748364.8 to 214748364.7 (
µ
m)
–2147483648 to 2147483647 (
×
10
-1
µ
m)
1 : inch
–21474.83648 to 21474.83647 (inch)
–2147483648 to 2147483647 (
×
10
-5
inch)
2 : degree –21474.83648 to 21474.83647 (degree) –2147483648 to 2147483647 (
×
10
-5
degree)
3 : pulse
–2147483648 to 2147483647 (pulse)
–2147483648 to 2147483647 (pulse)
Pr.56 Zero point return torque limit value
Set the value to limit the servomotor torque after reaching the creep speed during
machine zero point return.
Refer to section "12.4.2 Torque limit function" for details on the torque limits.
Pr.57 Speed designation during zero point shift
Set the operation speed for when a value other than "0" is set for " Pr.55 Zero
point shift amount". Select the setting from " Pr.48 Zero point return speed" or
" Pr.49 Creep speed".
0 : Designate " Pr.48 Zero point return speed" as the setting value.
1 : Designate " Pr.49 Creep speed" as the setting value.
Pr.58 Dwell time during zero point return retry
When zero point return retry is validated (when "1" is set for Pr.50 ), set the stop
time after decelerating in 2) and 4) in the following drawing.
Start position
Temporarily stop for
the time set in Pr. 58
Temporarily stop for
the time set in Pr. 58
1)
2)
3)
4)
5)
Pr.59
Absolute position restoration selection
In the absolute position detection system in the control unit "degree", set the mode
for absolute position restoration. Select either the standard mode or infinite length
mode for the setting.
0 : Standard mode
1 : Infinite length mode
Setting of other than "1" is regarded as "0", the standard mode.
After setting, turning the PLC READY signal [Y1D] from OFF to ON and making a
machine zero point return establishes the mode for absolute position restoration.
The established mode for absolute position restoration is stored into the axis
monitor " Md.121 Absolute position restoration mode".
For details of the mode for absolute position restoration, refer to section "12.6.2
Absolute position restoration mode switching function".
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......