5 - 24
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Pr.3 Movement amount per rotation (Al), Pr.4 Unit magnification (Am)
The amount how the workpiece moves with one motor rotation is determined by
the mechanical structure.
If the worm gear lead (mm/rev) is PB and the deceleration rate is 1/n, then
Movement amount per rotation (AL) = PB
×
1/n
However, the maximum value that can be set for this "movement amount per
rotation (Al)" parameter is 6553.5
µ
m (approx. 6.5mm). Set the "movement amount
per rotation (Al)" as shown below so that the "movement amount per rotation (AL)"
does not exceed this maximum value.
Movement amount per rotation (AL)
= PB
×
1/n
= Movement amount per rotation (Al)
×
Unit magnification (Am)
Note) The unit magnification (Am) is a value of 1, 10, 100 or 1000. If the "PB
×
1/n" value exceeds 6553.5
µ
m, adjust with the unit magnification so that the
"movement amount per rotation (Al) " does not exceed 6553.5
µ
m.
Example 1)
When movement amount per rotation (AL) = PB
×
1/n = 6000.0
µ
m (= 6mm)
Movement amount per rotation (AL)
= Movement amount per rotation (Al)
×
Unit magnification (Am)
= 6000.0
µ
m
×
1
Example 2)
When movement amount per rotation (AL) = PB
×
1/n = 60000.0
µ
m (= 60mm)
Movement amount per rotation (AL)
= Movement amount per rotation (Al)
×
Unit magnification (Am)
= 6000.0
µ
m
×
10
= 600.0
µ
m
×
100
M
G
1
n
P
f
P
B
PLC
PLC CPU
AD75
Servo amplifier
Servomotor
Workpiece
Encoder
Reduction gears
: Worm gear lead (mm/rev)
: Deceleration rate
: No. of encoder pulses (pulse/rev)
P
B
1/n
P
f
Movement amount per pulse l
l =
×
[mm/pulse]
1
n
P
B
P
f
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......