11.2.3 Setting the required parameters for JOG operation
The "Parameters" must be set to carry out JOG operation.
The following table shows the setting items of the required parameters for carrying out
JOG operation. When only JOG operation will be carried out, no parameters other than
those shown below need to be set. (Use the initial values or setting values within a
range where no error occurs for trouble-free operation.)
Setting item
Setting requirement
Factory-set initial value
(setting details)
Pr.1
Unit setting
3 (pulse)
Pr.2
No. of pulses per rotation (Ap) (Unit: pulse)
20000
Pr.3
Movement amount per rotation (Al) (Unit: pulse)
20000
Pr.4
Unit magnification (Am)
1 (1-fold)
Pr.7
Speed limit value (Unit: pulse/s)
200000
Pr.8
Acceleration time 0 (Unit: ms)
1000
Pr.9
Deceleration time 0 (Unit: ms)
1000
Pr.10
Bias speed at start (Unit: pulse/s)
0
Pr.12
Backlash compensation amount (Unit: pulse)
0
Pr.13
Software stroke limit upper limit value (Unit: pulse)
2147483647
Pr.14
Software stroke limit lower limit value (Unit: pulse)
–2147483648
Pr.15
Software stroke limit selection
0 (current feed value)
Pr.16
Software stroke limit valid/invalid setting
0 (invalid)
Pr.18
Torque limit setting value (Unit: %)
300
Param
e
ters
Pr.25
Size selection for acceleration/deceleration time
0 (1 word type)
: Setting always required.
: Set according to requirements (Leave set to the initial value when not used.)
REMARK
•
Parameter settings work in common for all control using the AD75. When carrying
out other control ("main positioning control", "advanced positioning control", "zero
point return positioning control"), the respective setting items must also be
matched and set.
•
Parameters are set for each axis.
•
Refer to "Chapter 5 DATA USED FOR POSITIONING CONTROL" for setting
details.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......