background image

Patent # US 9,679,735

RV CONTROL AND MONITORING SYSTEM

NCSP35CM

Installation and Operation Manual (English)

NCSP35CM

NCSP3DCCT

Summary of Contents for NCSP35CM

Page 1: ... Patent US 9 679 735 RV CONTROL AND MONITORING SYSTEM NCSP35CM Installation and Operation Manual English NCSP35CM NCSP3DCCT ...

Page 2: ......

Page 3: ... injury or property damage Operate only when you have a clear line of sight Do not operate any moving parts including but not limited to awnings jacks and slides unless you have a clear line of sight to the moving part The Mobile Application Display Commander or Body Control Module may be used only if you are giving instructions to and receiving instructions from another person at least age 18 or ...

Page 4: ...xt Editing 12 Scroll List Editing 14 Slides 15 Awning 15 Tank Heaters 15 Passcode 16 Set Passcode Timer 17 Change Passcode 17 Clear Passcode 17 Reset All Settings 18 MOBILE DEVICES 19 Pairing iOS Mobile Device to DC 20 Pairing Android Mobile Device to DC 23 Loading the DC Floor Plan 25 LANGUAGE SELECTION 26 CHECKING ACTIVE BLUETOOTH SESSION 27 HVAC 28 Vent Fans 28 Fan Only Mode 28 AC Cooling 28 He...

Page 5: ... Voltage with Low Voltage Alert HVAC AUX Motor Control Global Connect Precautions Use the Proper Power Supply This product is designed to operate with a 12 volt DC negative ground battery system the standard system in a North American vehicle Use Authorized Service Centers Do not attempt to disassemble or adjust this precision product contact a professional for assistance Avoid Moisture To reduce ...

Page 6: ...electing the Mounting Location Select a mounting location taking care to avoid the following Places exposed to heat radiating appliances such as electric heaters Adjacent to other equipment that radiates heat Under thermostats Poorly ventilated or dusty places Moist or humid locations CUTOUT FOR DISPLAY COMMANDER DC NOTE Before cutting the mounting hole make sure the area behind the mounting locat...

Page 7: ... WIRING The Wiring Diagram Depicts All The Wiring Connections Required For Proper Operation Of The Unit Body Control Module BCM Connections End of Line terminator resister End of Line terminator resister ...

Page 8: ...7 RV C SYSTEM LAYOUT AUX MOTOR CONTROL RELAY KIT OPTIONIAL End of Line terminator resister A A A ...

Page 9: ...Mode On Off Fan Cool Heat Auto Vent Open Shut Vent Fan Off Low Medium High Schedule Start time Stop time Awnings Awning Light No Yes Awning 1 In Out Awning 2 In Out Settings Bluetooth Scan Wi Fi On Off Scan Add Date time Edit Edit Alarms Awnings Lights Slides Passcode Setting Brightness Up Down Calibration Set Reset Floor plan OEM Floor Plan Default Floor Plan Information Information notes Softwar...

Page 10: ...the iN Command will lock down all motorized functions The Display Commander DC and mobile devices will also display Travel Lock Engaged and the affected buttons will cease to activate The lights water pump water heater and sensors will continue to function To turn the Travel Lock off press Disengage on the Display Commander DC inside the RV once the brake signal has been removed Travel Lock on the...

Page 11: ...tor to go in or out There are also buttons labeled AW 1 in and out AW 2 in and out that act as overrides for the optional AUX Motor Relay Control Kit The switches and buttons are momentary and will activate the component only while pressed in either direction DISPLAY COMMANDER BUTTONS The DC Display Commander has Power buttons on the front of it The Power Button turns the DC on and off long press ...

Page 12: ... this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter No change to the antenna or the device is permitted Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user s authority to operate the devi...

Page 13: ...Customize Notifications Touch Screen Calibration Control the Brightness of the DC screen View iN Command s Legal documents and customer support information View the software versions Check status of Global Connect Change Date and Time Switch the Menu Language between English and French The Administration page is used by the manufacturer When the Panic button is engaged from the DC Home Page or mob...

Page 14: ... to enter Edit page 3 Select the function to edit 4 Long press the intended text e g Light Group 2 5 Use the keyboard to edit the name then press Save Note Editing the text on the DC will not change the text on a device s App ...

Page 15: ...14 NCSP35CM Scroll List Editing 1 Select Settings 2 Press Edit to enter Edit page 3 Select the function to edit 4 Use the Up and Down arrows next to the function to move the item in the list ...

Page 16: ...n added to the system Note Desired devices need to be correctly wired to the BCM to function Awning Tank Heaters 1 Press on the tank readings at the top of the Home page to enter Tank Page 2 Press the box next to the Tank Heater function to turn off on Note The Tank Heater function is optional and available depending on Floor Plan ...

Page 17: ...16 NCSP35CM Passcode 2 1 Enter the correct passcode to proceed 1 Select Settings 2 Press Passcode to enter passcode setup 3 The passcode setup window will open ...

Page 18: ...imer select the idle time to activate the passcode protection Press the Clear Passcode to clear the passcode It will have the user create a new passcode 1 Press the Change Passcode button to change to a new passcode 2 Enter the new passcode Change Passcode Clear Passcode ...

Page 19: ...CM 1 Press the Reset All Settings Reset button to reset all settings This will restart the App take the user to the End User License Agreement and have the user setup a new passcode Reset All Settings 2 Confirm ...

Page 20: ...and at one time but only 1 iOS and 3 Android devices are able to be actively paired at the same time meaning 3 Android devices and 1 iOS device can all actively control the iN Command functions To use another device not actively paired to iN Command 1 device needs to shut down its iN Command App to allow another device to actively pair To do this shut down the App in the device s settings menu or ...

Page 21: ...iOS Mobile Device to DC 2 From the DC Home Page select Settings 2 2 Select Pairing to pair devices and view current paired devices 2 1 Select the Bluetooth tab 1 Enable Bluetooth in the system settings of the mobile device ...

Page 22: ... mobile device in the Unpaired Device list Select the device by pressing it 2 4 A Popup with the device name will apear on the display Press Pair 2 5 A Bluetooth Pairing request will appear on the DC and mobile device 2 6 Press PAIR on the DC 2 7 Press Pair on the mobile device ...

Page 23: ...be displayed in the Paired devices list on the DC 2 9 The DC will be displayed on the mobile device list in the format NCSPDCXXXXX Press the DC on the mobile device to connect with it 2 10 The mobile device now shows that the DC is connected ...

Page 24: ...Android Mobile Device to DC 1 From the App Home Page select settings 2 Select the Bluetooth tab 3 Press Scan to start scanning for Unpaired devices Locate the DC in the UnpairedDevice list Select the device by pressing it ...

Page 25: ...24 NCSP35CM 4 A Bluetooth pairing request will appear on the DC and mobile device 5 Press OK on the mobile device 6 The mobile device will be displayed in the Paired devices list on the mobile App ...

Page 26: ...ngs menu page Loading the DC Floor Plan 2 Press RV Sync button to Load the floor plan configuration from the DC The current settings will be lost replaced upon doing this When syncing via Global connect When syncing via Bluetooth When syncing has completed ...

Page 27: ...5CM 2 Select Language in the Settings page 3 Select one of the two options a English Select English language b French Select French language 1 Select Settings 4 Confirm for language selection LANGUAGE SELECTION ...

Page 28: ...s 2 The page shows information of current active Bluetooth devices To disconnect a handheld device press Disconnect or simply shut down the device s App This function is used to disconnect a device that is not actively being used and to allow another device to be connected ...

Page 29: ...speed can be switched between low medium and high 1 Select the desired Zone Press the Mode button to switch to Cool mode 2 Use the Set up and down arrows to set the desired temperature for the zone 3 Press the Fan button to switch between Low High and Auto fan speeds Vent Fans 1 To have just the AC fan operating in a zone select the desired Zone the press the Mode button to switch to Fan mode 2 Pr...

Page 30: ...Fan button to switch between Off Low High and Auto Off is not available in Electric Heat Source Auto Mode will automatically switch between Cool and Heat modes to reach the desired Set temperature Heat Mode is only available in Zones with Heat Mode selected on Floor Plan Auto 1 Select the desired Zone Press the Mode button to switch to Auto mode 2 Use the Set up and down arrows to set the desired ...

Page 31: ...ress the Clock icon at the bottom right corner of the HVAC home screen to enter the Schedule page HVAC Schedule 2 Use the Set up and down arrows to set the desired temperature 3 Use the Start and Stop arrows to set the time frame that you want the HVAC function to operate 4 Press the Schedule Button to turn On the schedule for the Zone selected ...

Page 32: ...or the Generator and HVAC scheduling functions 1 Select Settings Date Time 2 Press Date Time 3 In the Date Time page press the Edit tab to adjust the date and time 4 Use the Calendar to select the Date and the Clock to change the time Press Save ...

Page 33: ...he Settings page select the Software tab 4 In the software page you can choose to update the Floor Plan DC Version App Version and BCM Versions The system will look for specific file names for software updates File name NCSP3 DC VXXXX zip DC OS update xxxx is the version number File name ncspdcap_vxxxx apk DC App update xxxx is the version number File name ncspbcmvxxxx bin BCM update xxxx is the v...

Page 34: ...33 NCSP35CM 8 Press the BCM Version to update the BCM system Press Update 7 Press Confirm to continue 6 Framework update 5 Press the DC Version to update the DC OS sytem Press Update ...

Page 35: ...onics com in command If there is a software issue Call ASA Electronics Technical Support at 1 877 845 8750 or email them at info asaelectronics com 11 Press Floor Plan to select a floor plan Press Load to select the floor plan 10 Waiting for Update 9 Press the App version to update the DC App Press Update ...

Page 36: ...l Connect feature To setup a cloud account the device app first needs to be paired with the iN Command via Bluetooth Follow Bluetooth pairing instructions for your device 1 On the DC select Settings 2 Select the Wi Fi tab In the Wi Fi page press the Off button at the bottom of the page to turn Wi Fi On and Scan for available Wi Fi signals in your area 3 Select the Wi Fi SSID and enter the passcode...

Page 37: ... NCSP35CM 4 From the App Home Page select Settings Select the Global Connect tab 5 Select the Account tab 6 Press on the white bar next to Account and use the device keypad to enter a valid email address ...

Page 38: ... the device app Press Login 8 On the device turn Bluetooth off As long as you have internet available through your device and iN Command the device app will connect to iN Command through Global Connect 7 Press on the white bar next to Passcode and use the device keypad to enter a passcode for the account then press the Register button After the account is registered a notification of Register succ...

Page 39: ...ngs 3 Select Reset 4 Select on of the two options Default or OEM to restore to a previous state a Default restores to default settings from ASA b OEM restores to floor plan settings supplied by the RV Manufacturer FLOOR PLAN Customize or Reset Floor Plan settings Reset ...

Page 40: ...f AC Only Gas Electric Gas Electric HVAC 3 Off AC Only Gas Electric Gas Electric HVAC 4 Off AC Only Gas Electric Gas Electric Battery 2 Off On Note Default has options populated according to the floor plan loaded by OEM Any populated fields are dark blue Custom 1 Select the Custom in the floor plan Settings page 2 Press the box next to the function to turn off on and cycle through available option...

Page 41: ...attery 2 Off On with range from 10 8 to 14 4V Tanks Fresh 1 Off 0 3 1 3 Fresh 2 Off 0 3 1 3 Black 1 Off 2 3 3 3 Black 2 Off 2 3 3 3 Gray 1 Off 2 3 3 3 Gray 2 Off 2 3 3 3 Gray 3 Off 2 3 3 3 Interior Temperature High Off On with range from 30 F 90 F Low Off On with range from 30 F 90 F Note Only one HVAC Zone can be selected for notifications Notifications 3 Select Settings 4 Select Notifications ...

Page 42: ...41 NCSP35CM 3 To change notification settings press the box next to the function to cycle through options 4 When finished making changes press the Return button Then press Confirm ...

Page 43: ...SP35CM TOUCH SCREEN CALIBRATION 1 Select Settings 2 Select Calibration 3 To calibrate the Touch Screen select Set Follow the instructions The DC will restart after calibration 4 Touch the center of the cross ...

Page 44: ...rom the Administration page the App Data can be deleted the Generator Hour Meter can be set and the Water Tanks can be calibrated 1 From the Settings page press Administration 3 Make Selection 4 Select Tanks to set resistor reference value for every tank ...

Page 45: ...gramming and troubleshooting purposes Should there be a calibration issue call ASA Electronics Technical Support at 1 877 845 8750 or email them at info asaelectronics com 6 Press the App Data Delete button to clear current App data Note This will remove the floor plan settings from the RV Manufacturer 5 Press the Generator Hour Meter Set button to set the meter time ...

Page 46: ...DC Shut off all power to the DC and BCM Reconnect power wires to the DC Return power to the DC and BCM Press Reset button on the BCM Motor Functions do not activate Check for 12VDC on pin 41 Ensure the relay activates Relay not activating Replace the relay with one from an unused circuit See label on BCM cover for relay identification DC shows 0V and no functions activate from DC Check to ensure 4...

Page 47: ......

Reviews: