5 - 100
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
(3) Servo extension parameters
Servo amplifier
side parameter
Setting value, setting range
Setting value buffer
memory address
Item
No.
Abbre-
viation
Value set with peripheral
device
Value set with sequence
program
Default
value
Axis 1 Axis 2 Axis 3
Pr.127
Monitor output
1 offset
No.27
MO1
-999 to 999 (mV)
-999 to 999 (mV)
0
127
277
427
Pr.128
Monitor output
2 offset
No.28
MO2
-999 to 999 (mV)
-999 to 999 (mV)
0
128
278
428
Pr.130
Zero speed
No.30
ZSP
0 to 10000 (r/min)
0 to 10000 (r/min)
50
130
280
430
Pr.131
Error
excessive
alarm level
No.31
ERZ
0.025 to 25.000 (0.025rev)
1 to 1000 (0.025rev)
80
131
281
431
PI-PID control switching
0 : PI control is always
valid
0
1 : Switched to PID control
when value set to "PI-
PID switching position
droop" is reached or
exceeded during
position control
1
Pr.132
Option
function 5
No.32 OP5
2 : PID control is always
valid
2
0
132 282 432
Serial communication baud rate selection
–
0
H
–
1
H
–
2
H
–
3
H
Serial communication response delay time
–
0
H
–
1
H
Encoder pulse output setting selection
–
0
H
Pr.133
Option
function 6
No.33 *OP6
–
1
H
0000
H
133 283 433
Pr.134
PI-PID
switching
position droop
No.34
VPI
0 to 50000 (pulse)
0 to 50000 (pulse)
0
134
284
434
Pr.136
Speed
differential
compensation
No.36
VDC
0 to 1000
0 to 1000
980
136
286
436
* This parameter is made valid when the servo amplifier is powered OFF, then ON again after it has been transferred
from the AD75 to the servo amplifier.
Pr.127
Monitor output 1 offset
Set the offset voltage for the monitor output 1.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......