1 - 4
MELSEC-A
1 PRODUCT OUTLINE
(b) The control method designated with each positioning data includes position
control, speed control and speed/position changeover control.
(c) Continuous positioning with multiple positioning data items is possible with
the operation pattern set by the user using positioning data.
With the above multiple positioning data as one block, continuous
positioning of multiple blocks is possible.
(d) The zero point return control has been strengthened.
1) The near-point dog method (two types), count method (three types),
and data setting method (one type) zero point return methods have
been prepared as the "machine zero point return" zero point return
method.
2) To realize zero point return control to the machine zero point from a
random position, the zero point return retry function has been prepared.
(The machine zero point is the position used as the start point for
control such as positioning control. The machine zero point is
established with the machine zero point return in item 1) above.)
(e) Automatic trapezoidal acceleration/deceleration and S-pattern
acceleration/deceleration have been prepared as the
acceleration/deceleration methods. The user can select from automatic
trapezoidal acceleration/deceleration or S-pattern acceleration/deceleration.
(6) High-speed starting process
To quicken the process when starting positioning, the start processing time has
been reduced to 20ms.
When operation using simultaneous start function or interpolation operation is
executed, no start delay is generated between the target axes.
(Example) When operation is started with the simultaneous start function for axes
1 and 3: No start delay between axes 1 and 3.
When interpolation operation is started for axes 2 and axis 3: No start
delay between axes 2 and 3.
(7) Easy maintenance
The maintenance of the AD75 has been improved with the following matters.
(a) The various data, such as the positioning data and parameters, are stored
on a flash ROM in the AD75.
This allows the data to be held without a battery.
(b) The error display, machine system input state can be confirmed with the
17-segment display.
(c) The primary diagnosis has been improved by detailing the error details.
(d) Up to 16 history items each for the error and warning information can be
held, so the details of the errors and warnings that have occurred can be
confirmed easily.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......