10 - 11
MELSEC-A
10 ADVANCED POSITIONING CONTROL
10.3.4 Wait start
In a "wait start", the "condition data" conditional judgment designated in " Da.13
Parameter" is carried out for the positioning data set in " Da.11 Start data No.". If the
conditions have been established, the "start block data" is executed. If the conditions
have not been established, the control stops (waits) until the conditions are
established.
Section (2) shows a control example where the "start block data" and "positioning data"
are set as shown in section (1).
(1) Setting examples
(a) Start block data setting example
Axis 1 start
block data
Da.10
Shape
Da.11
Start data No.
Da.12
Special
start command
Da.13
Parameter
1st point
1: Continue
1
2: Wait start
3
2nd point
1: Continue
10
0: Normal start
–
3rd point
0: End
50
0: Normal start
–
•
•
* The "condition data Nos." have been set in "
Da.13 Parameter".
(b) Positioning data setting example
Axis 1 position-
ing data No.
Da.1
Operation pattern
1
01: Continuous positioning control
2
01: Continuous positioning control
3
00: Positioning complete
•
10
11: Continuous path control
11
11: Continuous path control
12
00: Positioning complete
•
50
00: Positioning complete
•
(2) Control examples
The following shows the control executed when the "start block data" of the 1st
point of axis 1 is set as shown in section (1) and started.
<1> The conditional judgment set in "condition data No. 3" is carried out before
execution of the axis 1 "positioning data No. 1".
Conditions established Execute positioning data No. 1, 2, and 3
Go to <2>.
Conditions not established Control stops (waits) until conditions are
established Go to <1>.
<2> Execute the axis 1 "positioning data No. 10, 11, 12, and 50" and stop the
control.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......