Da.1 Operation pattern
The operation pattern designates whether positioning of a certain data No. is to be
ended with just that data, or whether the positioning for the next data No. is to be
carried out in succession.
[Operation pattern]
Positioning complete
Independent positioning control
(Positioning complete)
Positioning
continued
Continuous positioning with one start signal
Continuous positioning control
Continuous path positioning with speed change
Continuous path control
......................................................................
.....
..........
1) Positioning complete..................... Set to execute positioning to the designated
address, and then complete positioning.
2) Continuous positioning control ..... Positioning is carried out successively in
order of data Nos. with one start signal.
The operation stops once at each positioning
data.
3) Continuous path control................ Positioning is carried out successively in
order of data Nos. with one start signal.
The operation does not stop at each
positioning data.
Da.2 Control method
Set the "control method" for carrying out positioning control.
Note)
•
When "JUMP command" is set for the control method, the " Da.8
Dwell time" and " Da.9 M code" setting details will differ.
•
Refer to "Chapter 9 MAIN POSITIONING CONTROL" for details on the
control methods.
•
If "degree" is set for " Pr.1 Unit setting", circular interpolation control
cannot be carried out. (The "Control method setting error" (error code:
524) will occur when executed.)
Da.3 Acceleration time No.
Set which of "acceleration time 0 to 3" to use for the acceleration time during
positioning.
0 : Use the value set in " Pr.8 Acceleration time 0".
1 : Use the value set in " Pr.26 Acceleration time 1".
2 : Use the value set in " Pr.27 Acceleration time 2".
3 : Use the value set in " Pr.28 Acceleration time 3".
Da.4 Deceleration time No.
Set which of "deceleration time 0 to 3" to use for the deceleration time during
positioning.
0 : Use the value set in " Pr.9 Deceleration time 0".
1 : Use the value set in " Pr.29 Deceleration time 1".
2 : Use the value set in " Pr.30 Deceleration time 2".
3 : Use the value set in " Pr.31 Deceleration time 3".
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......