Appendix - 31
MELSEC-A
APPENDICES
(2) Added buffer memory addresses
Buffer memory addresses
Axis 1
Axis 2
Axis 3
Name Used
function
64
65
214
215
364
365
Setting for the restart allowable range
when servo OFF to ON
Restart function
66 216 366
Near pass mode selection for path
control
Near pass mode function
91
241
391
Absolute position restoration selection
Absolute position restoration mode
switching function
138
288
438
Encoder output pulses
Encoder output pulse function*2
149
299
449
Servo parameter transmission setting
Encoder output pulse function*2
Slight vibration suppression function*2
876
976
1076
Regenerative load ratio
877
977
1077
Effective load ratio
878
978
1078
Peak load ratio
879
979
1079
Absolute position restoration mode
880
to
883
980
to
983
1080
to
1083
FeRAM access count
Axis monitor
1139
Parameter initialization request
Parameter initialization function
*2: Function of servo amplifier MR-J2S-B.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......