10 - 15
MELSEC-A
10 ADVANCED POSITIONING CONTROL
10.3.8 Repeated start (FOR condition)
In a "repeated start (FOR condition)", the data between the "start block data" in which
"6: FOR condition" is set in " Da.12 Special start command" and the "start block data"
in which "7: NEXT start" is set in " Da.12 Special start command" is repeatedly
executed until the establishment of the conditions set in the "condition data".
(The "condition data" designation is set in " Da.13 Parameter" of the "start block data"
in which "6: FOR condition" is set in " Da.12 Special start command".)
Section (2) shows a control example where the "start block data" and "positioning data"
are set as shown in section (1).
(1) Setting examples
(a) Start block data setting example
Axis 1 start
block data
Da.10
Shape
Da.11
Start data No.
Da.12
Special
start command
Da.13
Parameter
1st point
1: Continue
1
6: FOR condition
5
2nd point
1: Continue
10
0: Normal start
–
3rd point
0: End
50
7: NEXT start
–
•
•
* The "condition data Nos." have been set in "
Da.13 Parameter".
(b) Positioning data setting example
Axis 1 position-
ing data No.
Da.1
Operation pattern
1
01: Continuous positioning control
2
01: Continuous positioning control
3
00: Positioning complete
•
10
11: Continuous path control
11
00: Positioning complete
•
50
01: Continuous positioning control
51
00: Positioning complete
•
(2) Control examples
The following shows the control executed when the "start block data" of the 1st
point of axis 1 is set as shown in section (1) and started.
<1> Carry out the conditional judgment set in "condition data No. 5" for the axis 1
"positioning data No. 1".
Conditions not established Go to <2>.
Conditions established Go to <3>.
<2> Execute axis 1 "positioning data No. 1, 2, 3, 10, 11, 50, and 51", then go to
<1>.
<3> Execute axis 1 "positioning data No. 1, 2, 3, 10, 11, 50, and 51", then stop
the control.
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......