12 - 43
MELSEC-A
12 CONTROL AUXILIARY FUNCTIONS
12.5 Functions to change the control details
Functions to change the control details include the "speed change function", "override
function", "acceleration/deceleration time change function" and "torque change
function". Each function is executed by parameter setting or sequence program
creation and writing.
Both the "speed change function" or "override function" change the speed, but the
differences between the functions are shown below. Use the function that corresponds
to the application.
"Speed change function"
•
The speed is changed at any time, only in the control being executed.
•
The new speed is directly set.
"Override function"
•
The speed is changed for all control to be executed. (Note that this excludes
manual pulse generator operation.)
•
The new speed is set as a percent (%) of the command speed.
12.5.1 Speed change function
The speed control function is used to change the speed during control to a newly
designated speed at any time.
The new speed is directly set in the buffer memory, and the speed is changed by a
speed change command ( Cd.17 Speed change request) or external start signal.
The details shown below explain about the "speed change function".
(1) Control details
(2) Precautions during control
(3) Setting the speed change function from the PLC CPU
(4) Setting the speed change function using an external start signal
Summary of Contents for A1SD75M1
Page 2: ......
Page 20: ...A 18 MEMO...
Page 22: ...MEMO...
Page 27: ...1 5 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 42: ...1 20 MELSEC A 1 PRODUCT OUTLINE MEMO...
Page 52: ...2 10 MELSEC A 2 SYSTEM CONFIGURATION MEMO...
Page 111: ...5 21 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 115: ...5 25 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 123: ...5 33 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 127: ...5 37 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 167: ...5 77 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 193: ...5 103 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 276: ...5 186 MELSEC A 5 DATA USED FOR POSITIONING CONTROL MEMO...
Page 332: ...7 18 MELSEC A 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO...
Page 334: ...MEMO...
Page 422: ...9 64 MELSEC A 9 MAIN POSITIONING CONTROL MEMO...
Page 446: ...10 24 MELSEC A 10 ADVANCED POSITIONING CONTROL MEMO...
Page 472: ...11 26 MELSEC A 11 MANUAL CONTROL MEMO...
Page 576: ...12 104 MELSEC A 12 CONTROL AUXILIARY FUNCTIONS MEMO...
Page 745: ......