Install and Administer Trunks
Add TN1654 DS1 Converter (r only)
SI Installation and Upgrades
681
June 2004
Figure 275: DS1 Converter Connections for E1 75-ohm Service — Part 2
Set Circuit Pack Switches (TN1654 DS1
Converter)
Return to Task List
1
Set the configuration switches on the TN1654 as required per site.
2
Set Switch 6 down (disabled).
Switch 6 may not be present (or active) on all TN1654 DS1 Converter circuit packs.
3
Set Switch 1 up for T1 facilities.
All subsequent facility switch settings (Switches 2-5) reflect T1 framing on each of the 4
facilities. See
Examples of typical settings
on page 682.
4
Set Switch 1 down for E1 facilities.
All subsequent facility switch settings (Switches 2-5) reflect E1 impedance on each of the 4
facilities. See
Examples of typical settings
on page 682 for examples.