Install Fiber Optic Cable Pass-Thru Kit for SCC1 (Single-Carrier) Cabinets
DS1C Converter Complex Administration for TN574 Circuit Packs
SI Installation and Upgrades
217
June 2004
Figure 41: Fiber Link Administration form for TN574 Circuit Pack (DS1 Converter
Complex Administration) (page 2 of 3)
Return to Task List
add fiber-link next
Page 2 of 3
FIBER LINK ADMINISTRATION
A-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
DS1CONV Board Location: 01B01
DS1CONV Board Location: 02B01
DS1CONV Board Type: TN574
DS1CONV Board Type: TN574
DS1 CONVERTER FACILITIES
A
B
C
D
Facility Installed?
yes
no
no
no
Passes Far-end Clock?
yes
yes
yes
yes
Digital Data Compatible?
yes
yes
yes
yes
Line Coding:
ami-zcs ami-zcs
ami-zcs
ami-zcs
Framing Mode:
esf
esf
esf
esf
DS1CONV-1 Line Compensation:
1
1
1
1
DS1CONV-2 Line Compensation:
1
1
1
1
Facility A Circuit ID: 09876543
Distance to DSX-1 Interface (feet)
Equalizer
Setting
22 AWG ABAM & 24 AWG PDS
26 AWG PDS
1
1 to 133
0 to 90
2
133 to 266
90 to 180
3
266 to 399
180 to 270
4
399 to 533
270 to 360
5
533 to 655
360 to 450