Install and Wire Telephones
Task List: Install the Remote Network Interface
SI Installation and Upgrades
525
June 2004
7
If they are needed, enable
Cleared Alarm Notification
and
Restart
Notification
.
NOTE:
Avaya Media Gateway supports up to two OSS telephone numbers. Some services
contracts may require the second OSS telephone numbers and a different option in the
Alarm Origination to OSS Numbers
field to be administered.
Figure 202: Connections at Trunk/Auxiliary Field
Return to Task List
Install Off-Premises Station Wiring
Return to Task List
The local telephone company provides cabling outside the building for off-premises stations. The off-
premises stations can appear on any of the RJ21X network interfaces provided for the Central Office
(CO) trunks.
CAUTION:
Only an FCC-approved (or equivalent) analog type telephone (such as a 2500-type), can
be used as an off-premises station. The TN746B and TN2183 Analog Line circuit packs
can be connected to off-premises stations.
1
Install an A25D (male to male) cable between the RJ21X network interface and a sneak fuse
panel.
2
At the Main Distribution Frame (MDF), connect jumper wires between one row/connecting block
in the green field and up to three rows/connecting blocks in the purple field to concentrate the
analog line pairs.
Figure notes
1
To Network Interface Facility
2
To Control Carrier Auxiliary
Connector
3
One Pair of Wires
4
Twenty-fifth Pair of RJ21X
Network Interface Jack
25
50
IN
r758482b RBP 062696