System 75 XE to R8si (Blowback)
Task List: System 75 XE to R8si
274
SI Installation and Upgrades
June 2004
The results of system tests display on the monitor.
3
Verify that all tests pass.
If any of the terminal messages indicate a test has failed or if the message
spe down mode
is
displayed, refer to Maintenance for Avaya DEFINITY® Server SI (555-233-123) to clear the
trouble.
4
Type
set time
and press Enter.
See
Figure 70
.
5
Enter the date information and the time in 24-hour format. Enter either
daylight saving time
or
standard time
, depending on the current time in your time zone. If your area does not use
daylight saving time, set the value of
Daylight Savings Rule
to 0; otherwise, set
Daylight Savings Rule
to 1. Press Enter to set the date and time and ensure that the
system boots properly.
Figure 70: Typical Date and Time Screen
Return to Task List
System
Steps
AC
1
Set the circuit breakers on the AC power panel to ON.
2
Set the cabinet circuit breakers to ON.
This starts the system initialization and test. All red LEDs
on the circuit packs go on and then off.
DC
1
At the DC Battery Cabinet (if installed), set the circuit
breaker to ON.
2
At the DC Power Cabinet, set the circuit breaker(s) on the
rectifiers to ON.
This starts the system initialization and test. Some red
LEDs may be turned on, but they are turned off during the
boot-up process. No action is required.
DATE AND TIME
DATE
Day of the Week: Tuesday Month: June
Day of the Month: 26 Year: 2000
TIME
Hour: 20 Minute: 30 Second: XX Type: standard
Daylight Savings Rule: 1