G3iV4 to Avaya Communication Manager
Task List: G3iV4 to Avaya Communication Manager
78
SI Installation and Upgrades
June 2004
2
If the
save translation
command fails, do not continue. Record the error code that appears on the
screen and escalate the problem immediately.
Keep the translation media in a safe and secure place. In case of failure, you use this translation to
restore the system.
Return to Task List
Save translation, duplicated system [from
G3V4]
Return to Task List
To save translations on duplicated systems, the systems must be in sync or the command will fail. Both
switch processing elements (SPEs) must be functional: one in active mode and the other in standby mode.
1
Execute
status system 1
before you save translations.
Verify that conditions are normal — this can take a few minutes. If the system is not in a normal
condition, refer to the maintenance procedures; if maintenance fails, escalate the problem. DO
NOT PROCEED!
2
Type
save translation
and press Enter.
This takes about 10 minutes.
NOTE:
Do not press any keyboard key until after the terminal displays the success message. For
example, if you press Enter more than once after typing the command, the second Enter
erases the screen and you never see the success message.
3
If the
save translation
command fails, do not continue. Record the error code that appears on the
screen and escalate the problem immediately.
Store the translation media in a safe and secure place. In case of failure, you use this translation to restore
the system.
Return to Task List
Save announcements (TN750 or TN750B only)
[from G3V4]
Return to Task List
NOTE:
You do not need to save announcements for configurations containing the TN750C or
TN2501AP integrated announcement circuit packs, which contain on-board, nonvolatile
memory.