System 75 XE to R8si (Blowback)
Task List: System 75 XE to R8si
248
SI Installation and Upgrades
June 2004
Figure 50: Cabinet address-plug location
Return to Task List
Move 25-pair cables from System 75 to R8si [75 XE upgrade]
Return to Task List
1
Remove any reusable 25-pair cables from the rear of the old system.
For G3vs upgrades
Cables connecting the wall-mount G3vs and the si cabinet may be too short. If so,
replace these cables with new, longer cables.
2
Attach any reusable 25-pair cables to the needed connectors on the rear of the si cabinet.
3
Attach any new 25-pair cables to the needed connectors on the rear of the si cabinet.
4
Route the new cables to the MDF and attach.
Return to Task List