Add IP Solutions
Task list: Upgrade a TN802 to a TN802B
648
SI Installation and Upgrades
June 2004
13
Disconnect the monitor, keyboard, and mouse.
Figure 258: TN802B IP Interface faceplate
Return to Task List
Verify Circuit Packs
Return to Task List
1
Type
change circuit-pack
and press Enter.
2
On the
Figure 259, Circuit Packs - Screen 1,
on page 649, check the
Code
column to see if it says
DSMAPD
or
MEDPRO
.
3
To correct it, go to the entry just above the TN802B that says
DSMAPD
.
4
Type MEDPRO, and press Enter. Changing the one entry automatically changes the entry above
it. If it is in IP Trunk mode, you get the following error message:
MedPro type requires TN802 with application. Type MEDPRO on circuit-packs
form.
5
To complete the administration, refer to the Administration for Network Connectivity for Avaya™
Communication Manager (555-233-504) book.