Test the System
LED Indicators
SI Installation and Upgrades
491
June 2004
Figure 184: Sample Test Results for TDM Bus Port Network 1
Return to Task List
Test Tone-Clock Boards
Return to Task List
Testing the Tone-Clock board also detects problems with the TDM bus cables.
1
Type
test tone-clock 1a
and press Enter.
2
Verify page 1 displays the test results similar to
Figure 185, Sample Test Results for Tone-Clock
1A,
on page 491.
Figure 185: Sample Test Results for Tone-Clock 1A
Return to Task List
test tdm port-network 1
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
PN 01A TDM-BUS 294 PASS
PN 01A TDM-BUS 296 PASS
PN 01A TDM-BUS 297 ABORT 1005
PN 01B TDM-BUS 294 PASS
PN 01B TDM-BUS 296 ABORT 1005
PN 01B TDM-BUS 297 PASS
Command successfully completed
Command:
test tone-clock 1a
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A TONE-BD 46 PASS
01A TONE-BD 52 PASS
01AXX01 ETR-PT 42 PASS
01AXX01 ETR-PT 43 PASS
01AXX02 ETR-PT 42 PASS
01AXX02 ETR-PT 43 PASS
01AXX03 ETR-PT 42 PASS
01AXX03 ETR-PT 43 PASS
01AXX04 ETR-PT 42 PASS
01AXX04 ETR-PT 43 PASS
01AXX05 ETR-PT 42 PASS
01AXX05 ETR-PT 43 PASS
01AXX06 ETR-PT 42 PASS
01AXX06 ETR-PT 43 PASS