Release 9si/10si/Communication Manager 1.x to Communication Manager 2.1
Task list: R9si/10si/Communication Manager 1.x to Communication Manager 2.1
54
SI Installation and Upgrades
June 2004
Administer no-license/emergency numbers
Return to Task List
If the system enters a No-License mode, the switch only processes emergency calls. Use this procedure to
adminster the emergency numbers for No-License mode situations.
1
At the SAT, type
change system-parameters features
and press Enter.
The Feature-Related System Parameters screen displays.
2
In the
Emergency Numbers - Internal
field (optional) type a valid extension.
NOTE:
This field is intended for campus environments where there is an internal emergency
number that people are directed to use instead of 911. Calls to other extensions will not go
through. This number cannot be a hunt group or ACD number.
3
In the
Emergency Number - External
field (required) type a 21-digit, dialpad-valid
character string that can include trunk access codes. The default for this field is 911.
4
In the
No-License Incoming Call Number
field (optional) type a valid extension.
NOTE:
All calls are not rerouted to this number; only calls to this number get through. This
number cannot be a hunt group or ACD number.
5
Press Enter to save the changes.
Return to Task List
Set Daylight Savings rule
Return to Task List
1
Type
set time
and press Return.
The Date and Time screen appears.
2
In the
Type
field, type standard or daylight savings, depending on whether you are currently on
standard or daylight savings time.
3
In the
Daylight Savings Rule
field, set the rule value. If your area uses daylight savings
time, set the value to 1; otherwise, use the default setting of 0, no changeover to daylight savings
time.
4
Press Enter to set the time.
Return to Task List