Install and Wire Telephones
Auxiliary Connector Outputs
512
SI Installation and Upgrades
June 2004
* External alarm with signal incoming to system.
** External alarm with signal outgoing from system.
Y-BR
BR-Y
44
19
GND
-48
AUX Power
Y-S
S-Y
45
20
GND
-48
V-BL
BL-V
46
21
GND
-48
V-O
O-V
47
22
Not Connected
V-G
G-V
48
23
Ext Alarm A**
Ext Alarm Return
V-BR
BR-V
49
24
Not Connected
V-S
S-V
50
25
INADS Tip
INADS Ring
1 Color designation is the main wire color and the color of the stripe on the wire. The
following wire colors apply:
W-White
BL-Blue
O-Orange
G-Green
BR-Brown
S-Slate (Grey)
R-Red
BK-Black
Y-Yellow
V-Violet
Table 21: Auxiliary Lead Appearances at AUX Connector
Color
1
Pinouts
Output
Power
2 of 2