Use this Quick Start Guide to install, configure, and perform basic troubleshooting for the NVG558 and NVG578S gateways.

Power supply installation 

Connect the power supply cord to the Power In connector on the gate-

way and the other end into an appropriate electrical 

outlet.

Product ventilation

The gateway is intended for residential use. Position 

the gateway in a vertical position and where tem-

perature remains within a range of 32° – 104°F(0° – 

40°C) and heat from the unit itself is not trapped. 

There must be at least two inches (2”) of clearance 

on all sides except the bottom.

NVG558

NVG578S

Power

Broadband

WAN Ethernet

Wi-Fi

Voice

Front panel

Phone sockets

Reset button

LAN Ethernet ports 
with LED support

WAN/LAN switch
USB port

SFP+ port 

Fiber port 

Power button

Power In

LED

Status

Power

Solid Green

: The device is powered on.

Flashing Green

: The device is starting.

Solid Red

: Boot failure.

Flashing Red

:

 

Detecting factory reset (press and hold the recessed Reset button for 10 or more seconds to trigger the factory reset).

Broadband

Solid Blue

: Broadband internet connection is active.

Solid Red

: No IP address or authentication failed.

Off: No active broadband connection.

WAN

NVG578S/NVG558 (with Ethernet WAN interface)

Solid Green

: Ethernet WAN connection is good.

Flashing Green: 

Trying to connect to the available network.

Solid Red

:

 

No Ethernet WAN connection on the line.

NVG558 (with Cellular WAN interface)

Solid Green

: Cellular WAN connection is good.

Solid Yellow: 

Cellular WAN connection is fair.

Solid Red

Cellular WAN connection is poor.

Flashing Red

:

 

No cellular WAN connection on the line

.

Wi-Fi

Solid Green

: Wireless enabled (either radio).

Flashing Yellow

: Wi-Fi protected Set-up (WPS) is active.

Flashing Red

:

 

Flashes for 30 seconds to indicate the timeout or conflict of WPS.

Solid Red

:

 

Wireless network failure.

Off: Wireless is disabled for both the radios.

Voice

Solid Green

: All voice lines are registered and active.

Flashing Green

: A voice line is ringing or off-hook.

Solid Yellow

: Both lines of a two line system are provisioned with one unregistered.

Flashing Yellow: 

Both lines of a two line system are provisioned with one registered and ringing or off hook and the other 

one unregistered.

Solid Red

:

 

All provision voice lines are provisioned but not SIP registered.

Off: VoIP is not provisioned or the gateway is turned off.

LAN/WAN Ethernet LEDS

on rear panel RJ-45 ports

Solid Green

: Port is active.

Off: Port is not active.

Flashing Green

: Traffic is passing on the line.

LED descriptions

MPE/SAR/RF exposure information

This device was verified for RF exposure and found to comply with Council 

Recommendation 1999/519/EC and FCC OET-65 RF exposure requirements. This 

equipment complies with FCC radiation exposure limits set forth for an uncontrolled 

environment.

WARNING

: While this device is in operation, a separation distance of at least 30 cm 

(12 inches) must be maintained between the radiating antenna inside the EUT and 

the bodies of all persons exposed to the transmitter  to meet the FCC RF exposure 

guidelines.
Making changes to the antenna or the device is not permitted. Doing so may result in 

the installed system exceeding RF exposure requirements. This device must not be co-

located or operated in conjunction with any other antenna or radio transmitter.
Cet appareil répond aux directives d’exposition RF 1999/519/EC et FCC OET-65 sur la 

limitation d’exposition du public général aux champs électromagnétiques.

MISE AN GARDE

: Pour satisfaire aux exigences de la FCC et IC concernant l’exposition 

aux radiofréquences, une séparation de 30 cm ou plus doit être maintenue entre 

cet appareil et des personnes lors de fonctionnement du dispositif. Pour assurer la 

conformité, des opérations au plus près que cette distance n’est pas recommandée.
L’antenne utilisée pour cet émetteur ne doit pas être co-localisée ou fonctionner 

conjointement avec une autre antenne ou transmetteur.

Safety information

The following sections describe the safety guidelines for this product.

AC adapter

This product is intended to be supplied with a listed ARRIS desktop AC adapter marked 

Class 2 or LPS and rated 100 – 120V, 50/60Hz 1A, Output 12V, 3.75A for all NVG5X8 

series gateway models.

The AC power adapter supplied with this product is designed to ensure your personal 

safety and to be compatible with this equipment. Use only the power adapter that 

was provided with the gateway.

Please follow these guidelines:

•  Do not use the adapter in a high moisture environment. Never touch the adapter 

when your hands or feet are wet.

•  Allow adequate ventilation around the adapter. Avoid locations with restricted 

airflow.

•  Connect the adapter to a proper power source. The voltage and grounding 

requirements are found on the product case and/or packaging.

Adaptateur secteur

Cet appareil est destiné à être alimenté par une source d’alimentation directe fournie 

par ARRIS ou 2Wire, de « Classe 2 » ou marquée « LPS », et avec un courant de sortie 

de 100 – 120V, 50/60Hz 3.75A pour tous les modèles NVG5X8.

Le bloc d’alimentation secteur fourni avec ce produit a été conçu pour garantir votre 

sécurité et être compatible avec cet appareil.

Veuillez suivre les consignes suivantes:

•  N’utilisez pas l’adaptateur secteur dans un environnement hautement humide. Ne 

touchez jamais l’adaptateur secteur si vos pieds ou mains sont humides.

•  Laissez une ventilation adéquate autour de l’adaptateur secteur. Evitez les endroits 

où la circulation de l’air est insuffisante.

•  Branchez l’adaptateur secteur sur une prise respectant les spécifications sur la 

tension et la mise à la terre se trouvant sur la coque et/ou l’emballage du produit.

Telecommunication cord 

Caution: To reduce the risk of fire, use only No. 26 AWG or 

larger UL Listed or CSA Certified Telecommunication Line Cord.

Cordon téléphonique 

Attention: Afin de réduire le risque d’incendie, n’utilisez qu’un 

cordon téléphonique de calibre 26 AWG ou supérieur listé UL ou certifié CSA.

Internal telephone ports (VoIP)

Telecommunication equipment connected to this port (e.g.,via “Phone Lines 1 & 

2” port) should be UL Listed and the connections shall be made in accordance with 

Article 800 of the NEC.

Port téléphonique (VoIP)

Tout équipement de télécommunication téléphonique connecté à ce port doit être 

listé UL et les branchements doivent être fait conformément aux dispositions de 

l’Article 800 du Code national de l’électricité (NEC).

Repairs

Do not, under any circumstances, attempt any service, adjustments, or repairs on 

this equipment. Instead, contact your local ARRIS distributor or service provider for 

assistance. Failure to comply may void the product warranty.

Réparations

N’essayez en aucun cas d’effectuer des réparations, des ajustements ou des 

réparations sur cet équipement. Contactez plutôt votre distributeur ou fournisseur 

de services ARRIS local pour obtenir de l’aide. Le non-respect de cette consigne peut 

annuler la garantie du produit.

Location - electrical considerations

CAUTION: Due to risk of electrical shock or damage, do not use this product near 

water, including a bathtub, wash bowl, kitchen sink or laundry tub, in a wet basement, 

or near a swimming pool. Also, avoid using this product during electrical storms. Avoid 

locations near electrical appliances or other devices that cause excessive voltage 

fluctuations or emit electrical noise (for example, air conditioners, neon signs, high- 

frequency or magnetic security devices, or electric motors).

Emplacement – Considération électriques

AVERTISSEMENT: Pour éviter un risque de choc électrique, n’utilisez pas cet appareil 

à proximité d’une source d’eau, par exemple près d’une baignoire, un lavabo, une 

machine à laver, dans un garage humide ou près d’une piscine. Evitez aussi d’utiliser 

cet appareil durant un orage. Evitez de brancher cet appareil à proximité d’appareils 

électriques pouvant causer de large fluctuations de tension ou émettant du bruit 

électrique (tel que climatiseurs, enseignes au néon, dispositifs de sécurité magnétique 

ou de haute-fréquence, ou moteurs électriques).

Location - environmental considerations

Do not plug the power adapter into an outdoor outlet or operate the residential gateway 

outdoors. It is not waterproof or dustproof, and is for indoor use only. Any damage to 

the unit from exposure to rain or dust may void your warranty.
Do not use the residential gateway where there is high heat, dust, humidity, moisture, or 

caustic chemicals or oils.
Keep the gateway away from direct sunlight and anything that radiates heat, such as a 

stove or a motor.

•  Do not use the adapter if the cord becomes damaged.

•  Do not attempt to service the adapter. There are no serviceable parts inside. Replace 

the unit if it is damaged or exposed to excess moisture.

Lieu - considérations environnementales

Ne branchez pas l’adaptateur secteur sur une prise extérieure et n’utilisez pas la 

passerelle résidentielle à l’extérieur. Il n’est pas étanche à l’eau ou à la poussière, et 

est pour une utilisation à l’intérieur seulement. Tout dommage à l’appareil résultant 

d’une exposition à la pluie ou à la poussière peut annuler votre garantie. N’utilisez pas 

la passerelle résidentielle dans des endroits où la chaleur, la poussière, l’humidité, des 

produits chimiques ou des huiles sont caustiques. Gardez la passerelle à l’abri de la 

lumière directe du soleil et de tout ce qui dégage de la chaleur, tel qu’un poêle ou un 

moteur.

•  N’utilisez pas l’adaptateur si le cordon est endommagé.

•  N’essayez pas de réparer l’adaptateur. Il n’y a aucune pièce réparable à l’intérieur. 

Remplacez l’appareil s’il est endommagé ou exposé à un excès d’humidité.

Class 1M Laser Product
DANGER: 

Viewing the laser output with certain optical instruments (e.g. eye loupes, 

magnifiers and microscopes) within a distance of 100 mm may pose an eye hazard.

DANGER: 

Use of controls or adjustments, or performance of procedures other than 

those specified herein may result in hazardous radiation exposure.

DANGER: 

There must be a proper termination of all active fibers in the network.

IEC 60825-1:2014 - Safety of laser products - Equipment classification and requirements

EN 60825-1:2014 - Safety of laser products - Equipment classification and requirements

IEC 60825-2:2004+A1+A2 - Safety of laser products - Safety of OFCS

EN 60825-2:2004+A1+A2 - Safety of laser products - Safety of OFCS  

Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser 

Notice

No. 50, dated June 24, 2007

Produit laser de classe 1M
DANGER

: La visualisation de la sortie laser avec certains instruments optiques (loupes, 

loupes et microscopes, par exemple) à une distance de 100 mm peut présenter un 

risque pour les yeux. 

DANGER

: L’utilisation de commandes ou de réglages, ou l’exécution de procédures 

autres que celles spécifiées dans le présent document peut entraîner une exposition à 

un rayonnement dangereux. 

DANGER

: toutes les fibres actives du réseau doivent être correctement terminées

IEC 60825-1: 2014 - Sécurité des produits à laser - Classification et exigences de 

l’équipement 

EN 60825-1: 2014 - Sécurité des produits à laser - Classification et exigences de 

l’équipement 

IEC 60825-2: 2004 + A1 + A2 - Sécurité des produits laser - Sécurité des systèmes OFCS 

EN 60825-2: 2004 + A1 + A2 - Sécurité des produits laser - Sécurité des systèmes OFCS 

Conforme aux normes 21 CFR 1040.10 et 1040.11 à l’exception des déviations par 

rapport à l’avis laser No 50, daté du 24 juin 2007.

Trade Name

ARRIS

Responsible Party

ARRIS International plc.

Address

3871 Lakefield Drive, Suwanee, 

GA 30024, United States

Phone

1-866 362-7747

CBRS

Part 96.35   General authorized access use.

(a) General Authorized Access Users shall be permitted to use frequencies assigned to 

PALs when such frequencies are not in use, as determined by the SAS, consistent with 

§96.25(c).

(b) Frequencies that are available for General Authorized Access Use shall be made 

available on a shared basis.

(c) General Authorized Access Users shall have no expectation of interference protection 

from other General Authorized Access Users operating in accordance with this part.

(d) General Authorized Access Users must not cause harmful interference to and must 

accept interference from Priority Access Licensees and Incumbent Users in accordance 

with this part.

(e) General Authorized Access Users operating Category B CBSDs must make every 

effort to cooperate in the selection and use of available frequencies provided by an 

SAS to minimize the potential for interference and make the most effective use of the 

authorized facilities. Such users shall coordinate with an SAS before seeking station 

authorization, and make every effort to ensure that their CBSDs operate at a location, 

and with technical parameters, that will minimize the potential to cause and receive 

interference among CBSDs. Operators of CBSDs suffering from or causing harmful 

interference are expected to cooperate and resolve interference problems through 

technological solutions or by other mutually satisfactory arrangements.

616227-001-00   09/2019

Phone sockets

USB port

Broadband port

LAN Ethernet ports 
with LED support

Power button

Power In

Reset button
LTE connectors

Inserting your SIM card

Before inserting a SIM card into the 

gateway, ensure the SIM card is flat & 

the central part of the card is present 

and securely attached to the SIM 

frame.

5cm/2”

5cm/2”

5cm/2”

Gateway positioning, status indicator lights and port configuration

Proper positioning of the gateway is essential for proper cooling. 

Colored LEDs on the gateway indicate the status of various port activity.

Position the gateway in 

a vertical position.

Gateway positioning

Never

 insert a SIM card frame into 

the unit without the central SIM 

card present and securely attached 

to the outer SIM frame. Doing so 

will lock the SIM frame inside the 

unit preventing its removal.

Reviews: