R5/R6/R7/R8si to Avaya Communication Manager
Task List: R5/R6/R7/R8si to Avaya Communication Manager
122
SI Installation and Upgrades
June 2004
Set Daylight Savings Rule [from
R5/R6/R7/R8si]
Return to Task List
1
If your area does not use daylight saving time, set the value of
Daylight Savings Rule
to
0; otherwise, set
Daylight Savings Rule
to 1.
Figure 2: Typical Date and Time Screen
Deliver or install the License File [from
R5/R6/R7/R8si]
Return to Task List
CAUTION:
This procedure must be done immediately after you upgrade the software. If the license
file is not installed within 10 days, the switch enters a No-License mode and shuts down
all call processing.
New Duplicated G3r installations only
1
Retrieve the RFA License File with both serial numbers from the RFA Application.
2
Type
set time
and press Enter.
Ensure that the system date and time are set correctly.
3
Use one of these installation methods:
—
Direct connection between the switch and RFA
—
No connection between the switch and RFA
4
Type
save translation
and press Enter.
After the translations have been copied (about 10 minutes), the system returns an error code,
which must be a zero; otherwise, the translations are not copied.
5
Type
reset system 4
and press Enter.
Wait until the system has completely reset before continuing.
DATE AND TIME
DATE
Day of the Week: Tuesday Month: June
Day of the Month: 26 Year: 2000
TIME
Hour: 20 Minute: 30 Second: XX Type: standard
Daylight Savings Rule: 1