Upgrades to Avaya Commnication Manager Made Easy
Before you start
SI Installation and Upgrades
35
June 2004
Special Administration Requirements
Duplicated si systems, release 7.1 or later, must have the
SPE Interchange
field set correctly, or the
system will sometimes generate packet alarms that will prevent ISDN from working properly.
Type
change system-parameters maintenance
to display the MAINTENANCE-RELATED SYSTEM
PARAMETERS form and verify that the
SPE Interchange
field is set to daily.
Minimum required hardware
You need the following minimum required hardware to upgrade to Avaya Communication Manager.
display system-parameters maintenance Page 1 of 4
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1020000942
First OSS Telephone Number: 18004513036 Abbrev Alarm Report? y
Second OSS Telephone Number: Abbrev Alarm Report? n
Alarm Origination to OSS Numbers: first-only
Cleared Alarm Notification? n Suspension Threshold: 5
Restart Notification? y
Test Remote Access Port? y
CPE Alarm Activation Level: minor
Customer Access to INADS Port? y
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Start Time: 05 : 00 Stop Time: 06 : 00
Daily Maintenance: daily Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no System Clocks Interchange: no
SPE Interchange: daily EXP-LINK Interchange: no
Equipment
Notes
Basic si processor cabinet (SCC)
or
Basic si processor carrier (MCC)
Contains the following circuit packs:
•
TN780 or TN2182 tone clock
•
TN2404 processor, Vintage 3 or
higher
•
TN792 duplicate interface (opt)
•
TN2401 NetCtrl/PktIntf
Duplex processor cabinet (SCC)
or
Duplex processor carrier (MCC)
Contains the following circuit packs:
•
TN780 TN2182 tone clock
•
TN2404 processor, Vintage 3 or
higher
•
TN792 duplicate interface
•
TN2401 NetCtrl/PktIntf
AC Power unit
TDM/LAN bus terminator (SCC) Need 2