Option Switch Settings
Task List: Data Module Switches and Options
742
SI Installation and Upgrades
June 2004
About DCS Switch Settings
The Distributed Communications System (DCS) for a system is connected to the system through the
Processor Interface circuit pack. The first circuit can be connected directly to the DCS through the
processor interface (PI) connector on the rear of the control carrier.
Any of the remaining three circuits on the processor interface used to support the Distributed
Communications System (DCS) must be connected through a data module serving as the interface link.
The option settings for a 7400A Data Module are shown in
Table 33
. Refer to
Figure 295, Data Module
DIP Switch Locations:,
on page 742 for the location of the switches.
.
Figure 295: Data Module DIP Switch Locations:
Table 33: Data Module Option Switch Settings
DIP Switch
Function
Setting
1
With Phone
Without Phone
ON
OFF
5
Data Metering
No Data Metering
ON
OFF
8
Make Busy on Loc Loop
No Make Busy on Loc Loop
ON
OFF
2, 3, 4, 6, and 7
OFF
Figure notes
1
Data Module (7400A Shown)
2
DIP Switch
1
2
D TE
POW ER
TES T
DATA
ME TERING
7400B Data Module
AA CD RD SD
TR
O H
CH EC K
SPEED
D ATA
1
2
3
4
5
6
7
8
O