Option Switch Settings
Task List: Data Module Switches and Options
SI Installation and Upgrades
743
June 2004
About 7400D Data Module Option Settings
The option settings shown in
Table 34, 7400 Series Data Module Options (Answer Only Interface),
on
page 743 are for the Answer Only interface and are set from the front panel interface. Set only the desired
speed of the 7400D. All other default settings can be used.
NOTE:
It is recommended that CI and CH be set to ON, and DCD and DSR be set to NORMAL.
This allows login information to be displayed on the screen without having to send a
carriage return character.
Return to Task List
Table 34: 7400 Series Data Module Options (Answer Only Interface)
Set Option
Display
Abbreviatio
n
Possible Values
Default
Set 300 SPEED?
300
ON, OFF
ON
Set 1200 SPEED?
1200
ON, OFF
ON
Set 2400 SPEED?
2400
ON, OFF
ON
Set 4800 SPEED?
4800
ON, OFF
ON
Set 9600 SPEED?
9600
ON, OFF
ON
Set 19200 SPEED?
19200
ON, OFF
ON
Set ANSWER?
ANS
AUTO, MANUAL
AUTO
Set CI LEAD?
CI
ON, OFF
OFF (See Note)
Set CH LEAD?
CH
ON, OFF
OFF (See Note)
Set CTS LEAD?
CTS
NORMAL, ON
ON
Set DCD LEAD?
DCD
NORMAL, ON
ON (See Note)
Set DSR LEAD?
DSR
NORMAL, ON
ON (See Note)
Set DTR DETECT?
DTR
0, 10, 20, 30, 50, 100 MSEC
50
Set DTR LEAD?
DTR
EIA STANDARD,
IGNORE
EIA
STANDARD
Set LL LEAD?
LL
ON, OFF
OFF
Set REMOTE
LOOP?
REMLOOP
GRANT, DENY
GRANT
Set RI LEAD?
RI
CYCLE, ON
ON
Set RL LEAD?
RL
ON, OFF
OFF
Set SIGLS DISC?
SIGLS DISC
ON, OFF
ON
Set TIMING?
TIMING
INTERNAL, EXTERNAL
INT
Set TM LEAD?
TM
ON, OFF
OFF