R5/R6/R7/R8si to Avaya Communication Manager
Task List: R5/R6/R7/R8si to Avaya Communication Manager
130
SI Installation and Upgrades
June 2004
Check link status [from R5/R6/R7/R8si]
Return to Task List
This optional step is to make sure the links are in service before and after the upgrade.
1
Type
display communication-interface links
and press Enter. Write down all enabled links.
2
Type
status link
number
and press Enter for each enabled link.
3
Write down which links are enabled and in service.
NOTE:
If any links are enabled and out of service, resolve the problem before continuing the
upgrade.
4
Type
list signaling group
and press Return.
Note the signaling groups listed by number.
5
For each of the signaling groups listed, type
status signaling group
<number>
and press
Return.
6
If any of the links are not up, take the necessary corrective action to restore the link before
continuing with the upgrade.
Power up DEFINITY LAN Gateway system
[from R5/R6/R7/R8si]
Return to Task List
1
Log onto the DEFINITY LAN Gateway.
2
From the main menu, click Maintenance > Reset System > Reboot System.
Power up DEFINITY AUDIX system [from
R5/R6/R7/R8si]
Return to Task List
If the AUDIX was removed from the cabinet:
1
Re-install the AUDIX and allow it to boot up automatically.
2
Check for AUDIX System errors.
If the AUDIX remained in the cabinet but the cabinet was powered down:
3
Reseat the AUDIX
4
Power up the cabinet. The AUDIX reboots automatically.
5
Check for AUDIX System errors.