Install Telecommunications Cabling
Station Wiring Design
SI Installation and Upgrades
419
June 2004
Satellite Locations
Satellite locations are closets that provide an administration point (using cross-connect equipment) for
station cables and where adjunct power may be applied. The station cable circuits from the equipment
room MDF are 3-pair. At the satellite location, 4-pair circuits run to the information outlets. The
hardware used is 110-type terminal blocks.
Satellite Locations Using 110-Type Hardware
Each terminal block has a 3-pair (white field) and a 4-pair (blue field) located on the same terminal block.
The 110A-type terminal block that can be used is the 110AE1-75FT. It must be field-terminated to both
the white and blue fields.
The 300-pair 110P-type terminal blocks that can be used are:
•
110PE1-300CT/FT
—
25-pair connector on the white field and field-terminated on the blue field
•
110PE1-300FT
—
Field-terminated on both the white and blue fields
The 900-pair 110P-type terminal blocks that can be used are:
•
110PE1-900CT/FT
—
25-pair connector on the white field and field-terminated on the blue field
•
110PE1-900FT
—
Field-terminated on both the white and blue fields
Figure 144: Example of Extending 4-Pair Station Cables
1
2
3
4
5
5
crdfad1 CJL 101596
Figure notes
1
Station Cable
2
Information Outlet
3
451A In-Line Adapter
4
258A Adapter
5
4-Pair Station Cable