Install Additional Hardware
BRI Terminating Resistor Installation
SI Installation and Upgrades
577
June 2004
Install Cables (ISDN BRI)
Return to Task List
Install the cables from the cabinet to the MDF as required.
NOTE:
A TN556D ISDN BRI requires an 8-port backplane cable terminator (breakout
connector); aTN2198 ISDN BRI requires a 12-port backplane cable terminator. Connect
the 25-pair cable to the appropriate terminator.
Enter Added Translations (ISDN BRI)
Return to Task List
Administer the required translation data using the forms listed under 7500D voice terminals and 8500
voice terminals in the Administrator's Guide for Avaya™ Communication Manager (555-233-506).
Resolve Alarms
Return to Task List
Examine the alarm log. Resolve any alarms using the Maintenance for Avaya DEFINITY® Server SI
(555-233-123) documentation.
Save Translations (ISDN BRI)
Return to Task List
1
If the system is high or critical reliability, type
status system 1
and press Enter
to verify that the
system is in the
active/standby
mode.
2
Type
save translation
and press Enter. This instructs the system to take all translation
information in memory and write it to the translation cards.
3
If the system contains a TN750/B/C Announcement circuit pack, type
list configuration
software-version
and press Enter. To restore these announcements, type
restore
announcements
and press Enter.
4
Update backup cards, if required.