Install Fiber Optic Cable Pass-Thru Kit for SCC1 (Single-Carrier) Cabinets
DS1C Converter Complex Administration for TN574 Circuit Packs
214
SI Installation and Upgrades
June 2004
•
DS1CONV Board Location
—
Enter the cabinet, carrier, and slot that identifies the physical
location of DS1 Converter circuit pack in the second endpoint of the duplicate fiber link.
Endpoint-2’s duplicate along with Endpoint-1’s duplicate make up the duplicate fiber link called
the B-PNC link.
•
DS1CONV Board Type
—
Display-only field showing the type of DS1 Converter circuit pack
in Endpoint-2. The circuit pack type in Endpoint-2 (A-PNC) and Endpoint-2 (B-PNC) must be the
same. This field is updated via the Change Circuit-packs command.
Figure 40: Fiber Link Administration form (page 1 of 3)
Return to Task List
DS1C Converter Complex Administration for TN574
Circuit Packs
Return to Task List
Figure 41, Fiber Link Administration form for TN574 Circuit Pack (DS1 Converter Complex
Administration) (page 2 of 3),
on page 217 shows the fields available to administer the TN574 circuit
pack.
The following DS1 Converter Complex fields appear on Page 2 when the Is one endpoint remoted via a
DS1 Converter Complex? field is y.
NOTE:
When you administer DS1 Converter TN1654 circuit packs, different fields display.
add fiber-link next
Page 1 of 3
FIBER LINK ADMINISTRATION
Fiber Link #: 1
Is one endpoint remoted via DS1 Converter Complex? yes
ENDPOINT-1
ENDPOINT-2
(A-PNC) (A-PNC)
Board Location: 01E01
Board Location: 02A01
Board Type: ei
Board Type: ei
DS1CONV Board Location: 01B01
DS1CONV Board Location: 02B01
DS1CONV Board Type: TN574
DS1CONV Board Type: TN574
ENDPOINT-1 ENDPOINT-2
(B-PNC) (B-PNC)
Board Location: 01D01
Board Location: 02A02
Board Type: ei
Board Type: ei
DS1CONV Board Location: 01C01
DS1CONV Board Location: 02C01
DS1CONV Board Type: TN574
DS1CONV Board Type: TN574