Install and Connect Modems
Task List: Set up Modem Pooling
712
SI Installation and Upgrades
June 2004
Add Modem Pooling
Return to Task List
Modem Pooling supports 2 types of conversion resources: integrated and combined.
The integrated type requires a TN758 Pooled Modem circuit pack for each 2 conversion resources
provided.
The combined type requires a port on a TN754C Digital Line circuit pack and a port on either an 8-port
TN742, TN769; a 16-port TN746B; or a 24-port TN793/B, TN2793/B Analog Line circuit pack for each
conversion resource provided.
The pooled modem requires a WP90110 L7 power supply. Although an integrated conversion resource
can use either the L5 or L7, the combined only works with an L7.
CAUTION:
The L5 and L7 power supplies look identical. Check the list number on the power supply
before installing.
Task List: Set up Modem Pooling
1
Add Pooled Modem (Paradyne 3800 Series)
on page 712
2
Set the Modem Connected to Data Module
on page 713
3
Set the Modem Connected to the Data Terminal Equipment (DTE)
on page 713
4
Set 7400A and 7400B Options (Modem Pooling)
on page 713
Return to Task List
Add Pooled Modem (Paradyne 3800 Series)
Return to Task List
Use this procedure for Paradyne 3800 Series modems. For other types of modems, refer to the vendor’s
documentation.
The pooled modem requires a WP90110 L7 power supply. The L5 and L7 power supplies look identical.
Check the list number on the power supply before installing.
1
Determine the port assignment of the circuit packs to be added (if required).
2
Install the appropriate circuit packs in assigned carrier slot (if required).
3
Type AT&F&D2&S4\D3S2=128x7V2S7=60S85=1 and press Enter.
4
Type ATY0S10=100S78=2M0E0\N1&W and press Enter.
Return to Task List