R5/R6/R7/R8si to Avaya Communication Manager
Task List: R5/R6/R7/R8si to Avaya Communication Manager
SI Installation and Upgrades
115
June 2004
6
Type
display communication-interface processor-channels
and press Enter.
7
For each processor channel where the
Application
field is ISDN, record the information in all
fields.
If you must back out of the upgrade, you will need this information.
8
Type
change communication-interface processor-channels
and press Enter.
9
For each processor channel where the
Application
field is ISDN, clear the information from
all fields and press Enter.
10
Type
change communication-interface links
and press Enter.
11
For each PI extension where the
Prot
field is ISDN make these entries:
12
Press Enter.
13
For each PI extension where the
Application
field is ISDN:
a
Type
display data-module
[
PI EXT
] and press Enter. Record the information in each
field.
If you must back out of the upgrade, you will need this information.
b
Type
remove data-module
[
PI EXT
] and press Enter.
Return to Task List
Save translation [from R5/R6/R7/R8si]
Return to Task List
NOTE:
To save translations on duplicated systems, the systems must be in sync or the command
will fail.
For High and Critical Reliability only, execute
status system 1
before you save translations.
Verify that conditions are normal (this can take as long as 5 to 10 minutes). If the system refuses to go
into a normal condition, refer to the maintenance procedures; if that fails, escalate the problem.
1
Type
save translation
and press Enter.
This takes about 10 minutes.
NOTE:
Do not press any keyboard key until after the terminal displays the success message. For
example, if you press Enter more than once after typing the command, the second Enter
erases the screen and you never see the success message.
Field
Value
Est Conn
n
Prot
bx25
DTE/DCE
dte
Identification
[blank]