Adjuncts and Peripherals
Multimedia call handling (MMCH)
812
SI Installation and Upgrades
June 2004
Figure 313: Typical multimedia call handling connections
1
Each PC MMCH endpoint must contain a BRI adapter.
2
Connect a DCP telephone to a digital line circuit pack. The DCP telephone must be used in
conjunction with the PC. Refer to the tables at the end of this chapter for the pinout of the digital
line circuit pack.
3
Connect the PC BRI adapter to any BRI port on the Avaya Media Server. Refer to the tables at the
end of this chapter for the pinout of an ISDN BRI circuit pack.
Administer the system
1
Call INADS and notify the representative that the
Multimedia Call Handling (MMCH)?
field on page 2 of the customer-options form must be changed to y.
2
Logoff the terminal and then log back on the terminal to see your changes.
Administer the endpoints
1
Log in and enter
add data <next|or a valid extension number>
.
2
The data module form appears. On page 1 of the form, enter the
Data Extension:
xxxx
,
Type:
7500, the
Name:
user’s name (such as ProShare), and enter y in
Multimedia?
field.
3
On page 2 of the form, enter n in the
XID?
field, and enter n in the
MIM Support?
field and
press Enter.
Figure notes
1
DCP telephone, 2 or 4 wire to match
type of circuit pack
2
Personal computer
3
BRI adapter
4
D8W cord
5
103A or modular wall jack
6
Main distribution frame
7
25-pair cable to digital line circuit pack
8
25-pair cable to BRI circuit pack or NT1,
4-to-2 wire adapter
9
Avaya Media Server
10
Multimedia-interface circuit pack
11
Voice conditioner circuit pack