Install Fiber Optic Cable Pass-Thru Kit for SCC1 (Single-Carrier) Cabinets
Duplicated Fiber Link Administration
SI Installation and Upgrades
213
June 2004
Figure 39: Fiber Link Administration form
Return to Task List
Duplicated Fiber Link Administration
Return to Task List
Figure 40, Fiber Link Administration form (page 1 of 3),
on page 214 shows the fields available when
duplication is enabled.
The following fields appear when Administration of PNC Duplication is enabled on the System-
Parameters Customer-Options form:
•
Fiber Link #
—
Display-only field. From the command line, enter a 1- to 3-digit number to
uniquely identify a switch connection in the system and its duplicate if appropriate.
•
Is one endpoint remoted via DS1 Converter Complex?
—
Enter yes to specify that a DS1
converter complex is used to remote one endpoint. If yes is entered, A-PNC and B-PNC DS1
Converter (DS1CONV) Attributes must be administered on Pages 2 and 3 (respectively) of the
form.
•
Board Location
—
Enter the cabinet, carrier, and slot that identifies the physical location of a
circuit pack in the first endpoint of the duplicate fiber link. Endpoint-1’s duplicate along with
Endpoint-2’s duplicate make up the duplicate fiber link called the B-PNC link.
•
Board Type
—
Display-only field showing the type of circuit pack in Endpoint-1. The circuit
pack type in Endpoint-1 (A-PNC) and Endpoint-1 (B-PNC) must be the same.
•
DS1CONV Board Location
—
Enter the cabinet, carrier, and slot that identifies the physical
location of DS1 Converter circuit pack in the first endpoint of the duplicate fiber link. Endpoint-
1’s duplicate along with Endpoint-2’s duplicate make up the duplicate fiber link called the B-PNC
link.
•
DS1CONV Board Type
—
Display-only field showing the type of DS1 Converter circuit pack
in Endpoint-1. The circuit pack type in Endpoint-1 (A-PNC) and Endpoint-1 (B-PNC) must be the
same. This field is updated via the Change Circuit-packs command.
•
Board Location
—
Enter the cabinet, carrier, and slot that identifies the physical location of a
circuit pack in the second endpoint of the duplicate fiber link. Endpoint-2’s duplicate along with
Endpoint-1’s duplicate make up the duplicate fiber link called the B-PNC link.
•
Board Type
—
Display-only field showing the type of circuit pack in Endpoint-2. The circuit
pack type in Endpoint-2 (A-PNC) and Endpoint-2 (B-PNC) must be the same.
Page 1 of 1
FIBER LINK ADMINISTRATION
Fiber Link #: 1
Is one endpoint remoted via a DS1 Converter Complex? ___
ENDPOINT-1 ENDPOINT-2
(A-PNC) (A-PNC)
Board Location: _____
Board Location: _____
Board Type: xxx
Board Type: xxx