Check SPE
Return to Task List
1
Type
status system 1
and press Return.
Check these fields for the corresponding values:
— Maj/Min alarms = 0
— Service State = in service
Return to Task List
Verify the software version
Return to Task List
1
Type
list configuration software-version
and press Return.
The Software Versions screen appears.
2
In the UPDATE FILE section, check the
Update State
field for a software patch:
— If there is a patch number, then a patch has been applied.
— If the field is none in memory, there is no software patch in system memory.
If you need to restore the system to the old software version, you must also download a patch onto
the system.
3
In the SOFTWARE VERSION section note the current software version listed in the
Memory
Resident
field.
Ensure that the current software version is compatible with this software-only upgrade path.
Return to Task List
Verify system status
Return to Task List
1
Type
status system 1
and press Return.
Check these fields for the corresponding values:
— In the SPE ALARMS section,
MAJOR
and
MINOR alarms
= 0
—
Service State
= in service
2
If there are alarms, take the necessary corrective actions (
display alarms
).
3
Type
display errors
and press Return.
4
Examine the Hardware Error Log and record any Error Code 18 alarm that identifies existing
busyouts. After the upgrade you will restore the busyouts as they were (
Restore busyouts
).
5
For configurations with existing BX.25 links that are being retained after the upgrade, type
display communication-interface links
and press Return.