Label and connect cables [from
R5/R6/R7/R8si]
Return to Task List
1
To make reconnecting the cables simpler and more reliable, label every reusable connector cable
in the system.
2
Install new connector cables, as needed, onto the connectors at the rear of the cabinet.
3
Route the cables to the MDF and cross-connect as needed.
Return to Task List
Disable scheduled maintenance and alarm
origination [from R5/R6/R7/R8si]
Return to Task List
1
To prevent scheduled daily maintenance from interfering with the update or upgrade, type
change system-parameters maintenance
and press Enter.
2
If scheduled maintenance:
— has begun: set the
Stop Time
field to 1 minute after the current time.
— has not begun: set the
Start Time
field to at least 8 hours after the upgrade starts.
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms, resulting in
unnecessary trouble tickets.
3
Type neither in the
Alarm Origination to OSS Numbers
field and press Enter.
Return to Task List