Upgrade Firmware on Programmable Circuit Packs
Self and C-LAN-distributed download Procedure
728
SI Installation and Upgrades
June 2004
2
Look in the
Result
field for
FAIL/PASS
conditions.
The
Result
field in the screen shows
PASS
, indicating a successful test of the firmware
download circuitry.
If the
Result
field shows
FAIL
, refer to the maintenance book in the FW-DWNLD maintenance
object section, subsection entitled System Technician-Demanded Tests: Descriptions and Error
Codes. Resolve every error and rerun the test.
When the test passes, every specified resource is currently available for the scheduled download. Note,
however, that this does not guarantee the resource will still be available at the time of the download.
Backing out of a firmware download
To back out of a completed firmware download and revert to the previous image, follow the same
download procedure you did before, except use the previous firmware vintage instead. The exception is
TN799DP (C-LAN) and TN2501AP (VAL), which have a separate procedure.
Reverting to an older TN799DP or TN2501AP vintage
To revert back to the old firmware image file on a TN799DP (C-LAN) or TN2501AP (VAL) only:
1
Type
get boot-image
UUCSS
and press Enter to check the status of the firmware images on the
target circuit pack. .
2
Check the
Active Image:
field in the
Image 1
and
Image 2
columns to see where the
active image resides.
3
Check the
Date
and
Timestamp
fields to determine whether to revert back to a previous image.
In the following example, we are reverting back to Image 2, because it has the older date and time
stamp.
test firmware download SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
FW-DWNLD 1413 PASS
get boot-image 1C07
DISPLAY FIRMWARE IMAGE(S)
Image 1 Image 2
Board Type: TN2501 TN2501
FW Vintage: 02 01
HW Signature: 02 02
Suffix: A A
Date: 09/13/02 05/06/02
Timestamp: 10:30:50 12:42:18
CRC Checksum: Good Good
Active Image: Yes No