G3V4vs/R5vs/R6vs to Avaya Communication Manager
Task List: DEFINITY vs to Avaya Communication Manager
SI Installation and Upgrades
163
June 2004
3
In the
Emergency Number - External
field (required) type a 21-digit, dialpad-valid
character string that can include trunk access codes. The default for this field is 911.
4
In the
No-License Incoming Call Number
field (optional) type a valid extension.
NOTE:
All calls are not rerouted to this number; only calls to this number get through. This
number cannot be a hunt group or ACD number.
5
Press Enter to save the changes.
Set Daylight Savings rule [from
G3V4vs/R5vs/R6vs]
Return to Task List
1
If your area does not use daylight saving time, set the value of
Daylight Savings Rule
to
0; otherwise, set
Daylight Savings Rule
to 1.
Figure 7: Typical Date and Time Screen
Return to Task List
Check customer options [from
G3V4vs/R5vs/R6vs]
Return to Task List
High or Critical Reliability
1
Verify that the switches are in auto: Type
status system 1
and press Enter.
Verify that conditions are normal (this can take as long as 5 to 10 minutes). If the system refuses
to go onto a normal condition, refer to the maintenance procedures; if that fails, escalate the
problem.
All
1
Type
display system-parameters customer-options
and press Enter.
Check that the
G3 version:
field is V11.
DATE AND TIME
DATE
Day of the Week: Tuesday Month: June
Day of the Month: 26 Year: 2000
TIME
Hour: 20 Minute: 30 Second: XX Type: standard
Daylight Savings Rule: 1