background image

User Manual

Outboard Gateway YDOG-01

also covers models

YDOG-01N, YDOG-01R

Firmware version

1.00

 

2021

Summary of Contents for YDOG-01

Page 1: ...User Manual Outboard Gateway YDOG 01 also covers models YDOG 01N YDOG 01R Firmware version 1 00 2021...

Page 2: ...01 001 August 8 2021 Web http www yachtd com NMEA 2000 is a registered trademark of the National Marine Electronics Association SeaTalk NG is a registered trademark of Raymarine UK Limited Garmin is...

Page 3: ...nfiguration with a Hidden Button 17 VI Configuration with Installation Description Strings 19 VII Firmware Updates 26 Appendix A Troubleshooting 28 Appendix B NMEA 2000 Messages Supported by Device 30...

Page 4: ...programmed to issue high revolutions high temperature and low voltage warnings and set the state of the charge indicator displayed on MFD or NMEA 2000 display If you have a single battery on your boat...

Page 5: ...cost of equipment installation and configuration nor the shipping of the defective Device to the manufacturer 5 Responsibility of the manufacturer in case of any damage as a consequence of Device ope...

Page 6: ...plied with different types of NMEA 2000 connectors Models containing an R in the suffix of the model name are equipped with Raymarine SeaTalk NG compatible connectors Models containing N in the suffix...

Page 7: ...Engine hours resolution 1 second Operating temperature range 20 to 80 C Device case length without connector 40 mm Wire length 2000 mm Wire temperature range 50 to 180 C Weight 25 g Yacht Devices Ltd...

Page 8: ...he Device choose a dry mounting location Do not place the Device where it can be flooded by water or exposed to rain or water spray Please note that you may need to observe LED signals and or press th...

Page 9: ...the NMEA 2000 network backbone without a drop cable To connect the Device to a Simrad SimNet network with yellow connectors you can use an adaptor cable SimNet Female NMEA 2000 Micro Female Navico par...

Page 10: ...g Usually you need to wrap the wire 3 5 times around the spark plug wire and fix the loops with tape we recommend a tape rated for automotive use More turns make the signal stronger but it makes noise...

Page 11: ...it is better to enlarge the NMEA 2000 cable because it is designed to work in a harsh environment and is less susceptible to electromagnetic interference The ignition system sends from one impulse per...

Page 12: ...gram were received by the CAN Log Viewer from the Device The real time transmission of oscillograms significantly loads the NMEA 2000 network and we recommend turning off AIS and chart plotters to inc...

Page 13: ...ivider 8 at idle speed 600 900 RPM revolutions will be visible at MFD and will be 8 times higher 4800 7200 RPM But to complete the installation you need to test it at full speed because at full speed...

Page 14: ...for all engines except the port engine This can be done with the hidden button or with PC software If the current engine hours are known you can specify this number as fixed offset YD HOURS command We...

Page 15: ...GREEN but the second may change to RED during changes Please refer to Section III for details The third signal is GREEN if the Device receives messages listed at Appendix B see Receive column from the...

Page 16: ...onfiguration with button The LEDs behavior during configuration with the hidden button is described in Section V 3 Signals during firmware update The LEDs behavior during firmware update is described...

Page 17: ...ashes means that engine number is 1 starboard engine in twin engines configuration and so on Click the button and the setting value will be increased or reset to the smallest value if the maximum valu...

Page 18: ...ter noise filtering but counts up to 15000 pulses per minute two flashes mean algorithm 2 counts up to 70000 PPM and so on Algorithms 3 and 4 are experimental and will be changed in future versions Al...

Page 19: ...s to specify the device location or to leave notes or contact information They can be set with a PC software and a hardware gateway to the NMEA 2000 network Some models of chart plotters also allow ed...

Page 20: ...d this program runs on Microsoft Windows Mac OS X and Linux at http www yachtd com downloads A Yacht Devices NMEA 2000 Wi Fi Gateway Yacht Devices NMEA 2000 Ethernet Gateway Yacht Devices NMEA 2000 US...

Page 21: ...7488 127489 or 126993 Set transmitting interval for specified PGN the value is in milliseconds OFF or 0 disable periodic PGN transmission For default transmission intervals and PGNs description see Ap...

Page 22: ...ivider to 3 or higher value do not forget to change the algorithm of pulse counting next setting 2 3 YD ALG 1 4 Factory setting is 1 the number of built in algorithm for pulse counting The first algor...

Page 23: ...t and does not average readings if the value changes sharply When the Device is located inside the engine and far from the battery its power supply circuit may have interference that interferes with a...

Page 24: ...this with the data source For example you may have two temperature sensors with the data source 13 Freezer Temperature and instances 0 and 1 These can be interpreted as first and second freezers or po...

Page 25: ...is linked then its data will be used otherwise oil temperature data will be used This warning can only be issued when the engine is running 5 4 YD LOWVOLT 8 0 33 4 OFF This setting turns the low volta...

Page 26: ...ware version from our website http www yachtd com downloads Open the downloaded ZIP archive with the update and copy the YDOG01 BIN to the disk The README TXT file inside the archive can contain impor...

Page 27: ...site During the firmware upload the Device s LED flashes very fast When the firmware is updated Devices produce five half second RED signals and the CAN Log Viewer also informs you that the update is...

Page 28: ...onnector Device flashes GREEN GREEN RED GREEN but no data is available on MFD 1 Network error Check the list of external devices or NMEA 2000 devices on MFD and be sure that Outboard Gateway and other...

Page 29: ...it is susceptible to EMI Use proper NMEA 2000 data and power cables and avoid routing near EMI sources Non stable voltage readings 1 The power circuit is susceptible to EMI Use proper NMEA 2000 data a...

Page 30: ...nded Address PGN 65240 0xFED8 Yes No NMEA Group Function PGN 126208 0x1ED00 Yes Yes PGN List PGN 126464 0x1EE00 No Yes Heartbeat PGN 126993 0x1F011 No 60 sec Product Information PGN 126996 0x1F014 No...

Page 31: ...on Description Field 1 and Installation Description Field 2 can be changed with PGN 126208 professional NMEA 2000 installer software and hardware may be required 2 Periodic transmission intervals can...

Page 32: ......

Reviews: