V. Configuration with a Hidden Button
With this method, you can change engine number, RPM divider, and pulse counting
algorithm, as well as reset the Device to factory settings.
The status LED of the Device will constantly shine RED when the hidden button is
pressed.
1. Engine number programming
Click the hidden button (see Figure 1 in Section I) with the paper clip supplied with the
Device. A single click puts the Device into engine number programming mode.
After one second, the Device will issue a series of GREEN flashes. A single flash means
that the engine number is set to 0 (factory setting, port or single engine), two flashes
means that engine number is 1 (starboard engine in twin engines configuration), and
so on.
Click the button and the setting value will be increased (or reset to the smallest value,
if the maximum value has been exceeded), and the Device will issue a series of GREEN
flashes to visually confirm the new setting.
To leave programming mode, wait about 10 seconds. The Device will save your setting
and issue a normal mode flash sequence (four flashes, see Section IV). Please note that
your new settings will be applied only after saving and leaving programming mode.
2. RPM divider programming
To enter divider programming mode, click the button twice. A single flash in the
response sequence means that the divider is 0.5 (multiply to 2), two flashes mean
divider 1 (factory setting) and so on. Nine flashes indicates a divider of 8.