To program the Device, enter a special string starting with «YD:» to the installation
description field 2 in the Device properties. For example, «YD:DEV 1» (without
quotes) will change the NMEA 2000 device instance of the Device to 1. If the command
is accepted by the Device, it will add «DONE» to the entered text and «YD:DEV 1
DONE» will be displayed in this installation description field. If a command is entered
without the last parameter, the device replies with the current value of the parameter.
In Figure 1 on the previous page, you can see the process of programming the Device
with free CAN Log Viewer software (to open this window, select the item «NMEA
2000 Devices» in the «View» menu, refresh the list of devices, select the device
and click «Properties» button). You can download this program (runs on Microsoft
Windows, Mac OS X and Linux) at:
http://www.yachtd.com/downloads/
A Yacht Devices NMEA 2000 Wi-Fi Gateway, Yacht Devices NMEA 2000 Ethernet
Gateway, Yacht Devices NMEA 2000 USB Gateway or Yacht Devices NMEA 2000
Wi-Fi Router is required to connect the PC to the NMEA 2000 network. The CAN Log
Viewer also allows you to modify the NMEA 2000 device instance by entering a value
in the dedicated field (see «Address Claim» group on the screenshot). After entering
the command as shown in Figure 1 (click the «Update» button to apply changes), the
value in the «Device Instance» field will be changed to 1, and «Installation Details 2»
field will be changed to «YD:DEV 1 DONE».
Parameters in square brackets [] described below can be omitted to obtain the current
setting’s value.
1. Reset and NMEA 2000 specific commands
1.1 YD:RESET
This command resets Device settings to default values. Unlike all other commands, it
leaves Installation Description String 2 empty.
— 20 —
Summary of Contents for YDOG-01
Page 32: ......